Hongrijia Depurate Facility Science & Technology Co.,Ltd.
Hongrijia Depurate Facility Science & Technology Co.,Ltd.
53CFM Screw Air Filter With Anti-Corrosion Treatment
  • 53CFM Screw Air Filter With Anti-Corrosion Treatment
53CFM Screw Air Filter With Anti-Corrosion Treatment

53CFM Screw Air Filter With Anti-Corrosion Treatment

  • $155.38
    1-19 Piece/Pieces
  • $147.61
    ≥20 Piece/Pieces
Transportation:
Ocean, Land, Air, Express, Others
Port:
Shenzhen, Guangzhou , Shanghai
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Productivity: 500pcs per day
Supply Ability: 500PCS Per Days
Payment Type: T/T,L/C
Incoterm: FOB,CFR,CIF,EXW
Certificate: ce
HS Code: 8421399090
Transportation: Ocean,Land,Air,Express,Others
Port: Shenzhen,Guangzhou ,Shanghai
Product Description
Product Description

Feature & Advantage & Benefit

①Die-casting technology filter connection up to RC 4", capacity from 1.0m³/min to 48m³/min,flange connection is available.
②Both inside and outside housing with anti-corrosion treatment, prevent second pollution from itself.
③Low Pressure drop for ownership.
④Good filtration accuracy performance for contaminate, prevent oil mist, water mist or vapor and odor come down to your final equipment.
⑤Replace filter element easy and saving time
 
YF Series Activated Carbon Filter is design for the industries in Blow molding, Spraying Automation, Cosmetics,  etc.

7 Grades Filter Element:  PF/AO/AA/AX/ACS/AR/AAR
PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed
                                                                          
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).

For application in other working pressure, please refer to the correction factors.

Model Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W(Width) D(Depth) H(Height) A B C(clearance for housing)
YF010 RC1/2" 16.7  1.0  35.3  96 79 261 29 198 118
YF020 RC3/4" 25.0  1.5  53.0  96 79 261 29 198 118
YF030 RC3/4" 30.0  1.8  63.6  96 79 295 29 233 153
YF040 RC1" 33.3  2.0  71.0  96 79 295 29 233 153
YF060 RC1" 60.0  3.6  127.0  138 111 403 37 296 208
YF070 RC1" 83.3  5.0  177.0  138 111 503 37 396 303
YF080 RC1-1/2" 125.0  7.5  265.0  138 111 503 37 396 303
YF090 RC2" 166.7  10.0  353.1  174 142 736 58 607 469
YF100 RC2-1/2" 216.7  13.0  459.0  174 142 736 58 607 469
YF110 RC2" 283.3  17.0  600.0  174 142 1016 58 887 794
YF120 RC2-1/2" 316.7  19.0  671.0  174 142 1016 58 887 794
YF130 RC3" 416.7  25.0  883.0  220 184 793 74 649 514
YF140 RC4" 466.7  28.0  989.0  220 184 793 74 649 514
YF150 RC3" 683.3  41.0  1448.0  220 184 1050 74 906 764
YF160 RC4" 800.0  48.0  1695.0  220 184 1050 74 906 764
Technical requirements Maximum operating pressure: 10 barg   Operating temperature: 1.5°C~80°C.
Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

 

                                           AIR FILTER FOR Air compressorcompressed air filtercompressed air filter housing
 

Replacements & Spare Parts

YF010-YF040

Compressed Air Solution

YUKA air filter selection

 

Successful Cases

compressed air filter replacement

 

Coalescing Filters
Coalescing Air Filter is probably the most important items of purification requirements in a compressed air system,which are designed not only to filter oil vapor and water, but also to filter solid particulates to an acceptable level as small as 0.01micron in size. Usually, in the installation system, the first filter's purpose is to pre-filter, protect the high efficiency filters from bulk contamination so as to provide high quality compressed air. If the air filters worked under damp or full of water adsorption condition, it would prevent the compressed air from getting through the filter element and the air low would force the liquid to get through from the pores of the element media. thus increase working pressure drop and reduce filtration performance.

Air Compressor Filter
Oil vapor can easily get through the coalescing filters in a state of gaseous, so the adsorptive filter must provide large activated carbon adsorption bed. Because the damp air will reduce the adsorptive ability of the activated carbon, the adsorptive filter usually installed after the adsorptive dryer, in order to guarantee effective removal of oil vapor and peculiar odor. it's not used to remove the liquid oil or aerosols, thus poor maintenance and lack of pre-filter will accelerate its invalidation.

 

 

Send your message to this supplier

  • Ms. YUKA

  • Enter between 20 to 4,000 characters.