Hongrijia Depurate Facility Science & Technology Co.,Ltd.
Hongrijia Depurate Facility Science & Technology Co.,Ltd.
YUKA 127CFM Desiccant Filters For Air Compressor
  • YUKA 127CFM Desiccant Filters For Air Compressor
YUKA 127CFM Desiccant Filters For Air Compressor
YUKA 127CFM Desiccant Filters For Air Compressor
YUKA 127CFM Desiccant Filters For Air Compressor

YUKA 127CFM Desiccant Filters For Air Compressor

  • $208.82
    1-19 Piece/Pieces
  • $192.68
    ≥20 Piece/Pieces
Transportation:
Ocean, Land, Air, Express, Others
Port:
Shenzhen, Guangzhou , Shanghai
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: CHINA
Productivity: 20,000pcs per month
Supply Ability: 20,000PCS Per Month
Payment Type: T/T,L/C
Incoterm: FOB,CFR,CIF,EXW
Certificate: CE
HS Code: 8421399090
Transportation: Ocean,Land,Air,Express,Others
Port: Shenzhen,Guangzhou ,Shanghai
Product Description
Product Description

Compresses air solution in scientifically will be highly improved the efficiency for ownership, saving energy and saving money during the whole process. How to choose a Aluminum Air Filter will be an important question for everyone before they make decision. Below is some tips for you to select Air Compressor Filter for your precess.

①Assess the requirements of your application. Different industry require different solution. ②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. ③Any specific micron of filtration performance you required?
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) ⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment.  

Feature & Advantage

①Filtration performance up to 99.99% under the rate working conditions

②Coalescing Air Filter case, with 15 years serve life, lowest ownership overall cost

③7 Layers for filter element, fiber glass material, PF/AO/AA/AX with 4000-6000 hours spanlife

④Effectively filter solid particles up to 0.01 microns, suspended oil up to 0.003mg/m³

⑤Die-casting technology filter connection up to RC 4", capacity from 1.0m³/min to 48m³/min

⑥Both inside and outside housing with anti-corrosion treatment, prevent second pollution from itself

⑦Low Pressure drop for ownership
⑧Replace filter element without third-party or any tools

7 Grades Filter Element in Detail

PF: As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible

AO: High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w).

AA: High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w)

AX: Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w)

ACS: Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w)

AR: Dust particles whose diameter more than 1μm can be removed
AAR: Dust particles whose diameter more than 0.01μm can be removed

Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).For application in other working pressure, please refer to the correction factors. 
Model Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W(Width) D(Depth) H(Height) A B C(clearance for housing)
YF010 RC1/2" 16.7  1.0  35.3  96 79 261 29 198 118
YF020 RC3/4" 25.0  1.5  53.0  96 79 261 29 198 118
YF030 RC3/4" 30.0  1.8  63.6  96 79 295 29 233 153
YF040 RC1" 33.3  2.0  71.0  96 79 295 29 233 153
YF060 RC1" 60.0  3.6  127.0  138 111 403 37 296 208
YF070 RC1" 83.3  5.0  177.0  138 111 503 37 396 303
YF080 RC1-1/2" 125.0  7.5  265.0  138 111 503 37 396 303
YF090 RC2" 166.7  10.0  353.1  174 142 736 58 607 469
YF100 RC2-1/2" 216.7  13.0  459.0  174 142 736 58 607 469
YF110 RC2" 283.3  17.0  600.0  174 142 1016 58 887 794
YF120 RC2-1/2" 316.7  19.0  671.0  174 142 1016 58 887 794
YF130 RC3" 416.7  25.0  883.0  220 184 793 74 649 514
YF140 RC4" 466.7  28.0  989.0  220 184 793 74 649 514
YF150 RC3" 683.3  41.0  1448.0  220 184 1050 74 906 764
YF160 RC4" 800.0  48.0  1695.0  220 184 1050 74 906 764
Technical requirements Maximum operating pressure: 10 barg   Operating temperature: 1.5°C~80°C.
Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

 
adsorption air filterinlet air filterpipeline compressor filter

Accessories

YF060-YF080

Compressed Air Solution

Air filter Applied in Dairy products & Pharmaceutical & Breathe Air

Product Application                                                                                       
vessel compressed air filter

 

Send your message to this supplier

  • Ms. YUKA

  • Enter between 20 to 4,000 characters.