Proximity Sensor SE-M8TN2/M8TP2 (Inductive Proximity Sensor Cylindrical)

  • Switch Proximity Sensors Lead Out. The output types of DC 3-wire proximity sensors are NPN and PNP, PNP output proximity sensors are generally used in plc or computer as a control command more, NPN output proximity sensors for the control of DC relays more, in practice, according to the control NPN output proximity sensors are more often used to control DC relays.
  • At present, the main products are: safety light curtain, photoelectric switch series, proximity switch series, optical fiber sensor series, ultrasonic sensor, intelligent sensor, displacement sensor, gas pressure sensor, etc. Look forward to your cooperation!


Size

M8

M12

M18

M30

Model

SE-M8T□□

SE-M12T□□

SE-M18T□□

SE-M30T□□

Maximum Sensing Distance

1.5mm±15%

2.0mm±15%

5mm±15%

10mm±15%

Stable Sensing Distance

0-1.2mm

0-1.6mm

0-4mm

0-8mm

Differential Travel

10% max of the sensing distance

Standard Sensing Object

Iron: 8*8*1mm

Iron: 12*12*1mm

Iron: 18*18*1mm

Iron: 30*30*1mm

Power Supply Voltage

12 to 24V DC Pulse (p-p) 10% max

Current Consumption

13mA max

Switching Capacity

100mA max

Differential Travel Frequency

2kHz

1.5kHz

0.6kHz

0.4kHz

Circuit Protection

Reverse connection,  surge absorption,  load short circuit protection

Working Status Indicator

Action display(Red LED)

Ambient Temperature

Operating: -25 to +70℃, Storage: -40 to +85℃(With no icing)

Ambient Humidity

Operating,  Storage: 35 to 95%RH

Residual Voltage

2V max(Load: 200mA, cable length: 2m)

Insulating Resistance

50M Ωmax.(DC500V)  Between current-carrying parts and case

Voltage Withstand

AC 1000V 50/60Hz 1min    Between current-carrying parts and case

Vibration

Durable

10 to 55Hz Complex Amplitude 1.5mm each in X, Y, and Z directions 2h

Shock

Durable

500m/s² each in X, Y, and Z directions 10 times

1000m/s² for 10 times each in X, Y, and Z directions

Protective Structure

IEC Specification IP67

Material

Case

Brass

Sensing surface

PBT

Quality

Approx: 55g

Approx: 65g

Approx: 140g

Approx: 190g

Accessories

Two nuts, one toothed spacer


                                                                                                                                                                                                                                                                                                