Switching Model 120W 240W 360W LED Power Supply
-
$3.00≥100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Transportation:
- Ocean, Land, Air, Express
- Port:
- Shenzhen, Shekou
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Shenzhen |
---|---|
Productivity: | 20000pcs per week |
Supply Ability: | 20000pcs per week |
Payment Type: | L/C,T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Certificate: | ISO9001 |
HS Code: | 8504401400 |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Shekou |
Switching Model 120W 240W 360W LED Power Supply
Switching power supply products are widely used in industrial automation and control, military equipment, scientific research equipment, LED lighting, industrial equipment, communications equipment, electrical equipment, instrumentation, medical equipment, semiconductor refrigeration heating, air purifier, electronic refrigerator, Lighting, communications equipment, audio-visual products, security monitoring, LED light bags, computer chassis, digital products and equipment, and other fields.
For this item, followed are the details:
1. Low price and reliable perfermence.
2. 105 `C output capacitor
3. AC input power suitable for the world
4. High efficiency and low operation temperature.
5. Soft-start current can reduce the AC input impact effectidy.
6. With short-circuit and overload protection.
7. Compact size, light weight.
8. 100% full-load buming test.
9. installed with EMI filter, minmum wave.
Details:
Model |
S-350-5V |
S-350-12V |
S-350-24V |
DC Output Voltage |
5V |
12V |
24V |
Iutput Voltage Error |
± 2% |
± 1% |
± 1% |
Rated Output Current |
50A |
30A |
14.6A |
Output Current Range |
0-50A |
0-30A |
0-14.6A |
Tripple and Noise |
150mVp-p |
150mVp-p |
150mVp-p |
Iniet Stability |
± 0.5% |
± 0.5% |
± 0.5% |
Tolerance Voltage |
± 1% |
± 0.5% |
± 0.5% |
DC Output Power |
250W |
348W |
350w |
Efficiency |
76% |
78% |
80% |
Adjustable Range for DC Voltage |
4.5-5.6V |
10-13.2V |
20-26.4V |
AC Input Voltage Range |
90~132VAC/180~264VAC selected by switch 47~63Hz; 240~370VDC |
||
Input Current |
6.5A/115V 4A/230V |
||
AC Inrush Current |
Cold-Start Current: 25A/115V, 50A/230V |
||
Leakage Current |
<3.5mA/240VAC |
||
Overload Protection |
105%~150% Type: Cut Output, Reset: Auto Recovery |
||
Over Voltage Protection |
Yes |
||
High Temperature Protection |
Yes |
||
Temperature Coefficient |
± 0.03% /°C (0~50°C) |
||
Start, Rise, Hold time |
200ms, 100ms, 20ms |
||
Vibration |
10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axes |
||
Withstand Voltage |
Between Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVAC |
||
Isolation Resistance |
Input and Output Intermal: Input and Enclosule, Output and Enclosure: 500VDC/100M Ohms |
||
Working Temperature and Humidity |
`-10°C~+60°C (Refer to Output Dreating Cutive), 20%~90%RH |
||
Storage Temperature and Humidity |
`20°C~+85°C, 10%~95%RH |
||
Overall Dimension |
210*110*50 mm |
||
Weight |
715g |
||
EMC Standards |
Meet FCC Part 15J Conduction class B |

Please Note:
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%Rh, Humidity.
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF capacitor short-circuit for interrupting.
4. Inlet Voltage Stability test: when is over load, the lowest voltage of inter is representative to the highest voltage.
5. Load stability test: the load is from 0% to 100%, others 60%.
6. C3.4 must be knocked down.
Applications:
•Office , Artwork, Display items lighting;
•Household lighting;
•Commercial lighting, such as Flood light, Down light, Flexible strip light, Wall washer, etc;
•Hotel, Restaurant lighting;
•Other public facility lighting.
Related Keywords