HLG-150H Meanwell Waterproof LED Power Supply
- Payment Type:
- T/T, Paypal, Money Gram, Western Union
- Incoterm:
- FOB, CIF
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 3 Days
- Transportation:
- Ocean, Land, Air
- Port:
- Shenzhen, Guangzhou, Hongkong
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Guangdong, China |
---|---|
Productivity: | 20000pcs per month |
Supply Ability: | 5000pcs per month |
Payment Type: | T/T,Paypal,Money Gram,Western Union |
Incoterm: | FOB,CIF |
Transportation: | Ocean,Land,Air |
Port: | Shenzhen,Guangzhou,Hongkong |
HLG-150H Meanwell Waterproof LED Power Supply
Products Description
Waterproof 150W Single Output Switching Power Supply, the following model widely used with Iseeled`s led lamps, HLG-150H-12, HLG-150H-15, HLG-150H-24,etc some other model for special lamps with different input voltage.
HLG-150H-12 Blank : IP67 rated. Cable for I/O connection.
HLG-150H-12A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
HLG-150H-12B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or PWM signal or resistance.
HLG-150H-12D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
Model |
HLG-150H-12 |
HLG-150H-15 |
HLG-150H-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
|||
7.5-12.5A |
6-10A |
3.8-6.3A |
||
RATED POWER |
150W |
150W |
151.2W |
|
VOLTAGE ADJ. RANGE |
10.8-13.5V |
13.5-17V |
22-27V |
|
Input |
Voltage Range |
90-264VAC 127-370V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
92% |
92.5% |
93.5% |
|
AC CURRENT (Typ.) |
1.7A / 115VAC 0.75A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14-17V |
18-21V |
28-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
100 ℃ up or less10 ℃ (RTH2) |
|||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down |
||||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
192.2K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
228*68*38.8mm (L*W*H) |
|||
PACKING |
1.15Kg; 12pcs/14.8Kg/0.8CUFT |
|||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Type A only. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. Note
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.