MW Waterproof Power Supply Landscape Lighting Transformer
- Payment Type:
- T/T, Paypal, Money Gram, Western Union
- Incoterm:
- FOB, CIF
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 3 Days
- Transportation:
- Ocean, Land, Air
- Port:
- Shenzhen, Guangzhou, Hongkong
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Guangdong, China |
---|---|
Productivity: | 20000pcs per month |
Supply Ability: | 5000pcs per month |
Payment Type: | T/T,Paypal,Money Gram,Western Union |
Incoterm: | FOB,CIF |
Transportation: | Ocean,Land,Air |
Port: | Shenzhen,Guangzhou,Hongkong |
MW Waterproof Power Supply Landscape Lighting Transformer
Products Description
Waterproof 240W Single Output Switching Power Supply, the following model widely used with Iseeled`s led lamps;
HLG-240-12, HLG-240-15, HLG-240-24,etc some other model for special lamps with different input voltage.
The Meanwell Waterproof 240W HLG-240 Power Supply Landscape Lighting Transformer which provide 12V DC output, 15V DC output, 24V DC output model, which can widely used for the led lamp we provide, including the LED Wall Washer Light, LED Flood Light, LED Spot Light, Underground LED light, Underwater LED light, LED window light, and also the led linear tube, led linear bar, 3D led tube, 3D led ball, led pixel lights, etc.
HLG-240-12 Blank : IP67 rated. Cable for I/O connection.
HLG-240-12A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
HLG-240-12B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or PWM signal or resistance.
HLG-240-12C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
HLG-240-12D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
Model |
HLG-240-12 |
HLG-240-15 |
HLG-240-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer or through output cable |
|||
8-16A |
7.5-15A |
5-10A |
||
RATED POWER |
192W |
225W |
240W |
|
VOLTAGE ADJ. RANGE |
11.2-12.8V |
14-16V |
22.4-25.6V |
|
Input |
Voltage Range |
90-264VAC 127-373V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
90% |
90% |
93% |
|
AC CURRENT (Typ.) |
4A / 115VAC 2A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed. |
|||
OVER VOLTAGE |
13.5-18V |
17.5-21.5V |
27-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
105 ℃ up or less10 ℃ (TSW1) |
95 ℃ up or less5 ℃ (TSW1) |
||
|
Protection type : Shut down and latch off o/p voltage, re-power on to recover |
|||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240 C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved, J61347-1, J61347-2-13 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
207.9K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240-C) |
|||
PACKING |
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C) |
Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.Related Keywords