Firstpower Tech. Co., Ltd.
Firstpower Tech. Co., Ltd.
Wind generation Reserve Battery 12V70AH  Battery
  • Wind generation Reserve Battery 12V70AH  Battery
Wind generation Reserve Battery 12V70AH  Battery

Wind generation Reserve Battery 12V70AH Battery

Payment Type:
L/C, T/T, D/P
Incoterm:
FOB, CFR, CIF
Min. Order:
100 Piece/Pieces
Min. Order:
100 Piece/Pieces
Delivery Time:
30 Days
Transportation:
Ocean, Land
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: china
Productivity: 2000, 000kvah/ Year
Supply Ability: 2000, 000kvah/ Year
Payment Type: L/C,T/T,D/P
Incoterm: FOB,CFR,CIF
Certificate: iso,UL,CE
Transportation: Ocean,Land
Product Description
Product Description
Reserve Battery LFP1270S,capacity :12V70Ah batteries  is Sealed Lead Acid Battery. We welcome orders with "FirstPower" brand; We are also flexible to accept orders on OEM basis.
Contact us now! Your partnership with FirstPower
will prove worthy of it.
can be used for just about every application, including: UPS Backup Systems, Alarm Systems, Fire Alarm Systems, Medical Equipment, Test Equipment, and much more. 

Solar power
 

Specifications

Nominal Voltage

12 V

Capacity

(25)

10HR(10.8V)

70 Ah

5HR(10.5V)

61.5Ah

1HR(9.60V)

43.4Ah

Dimension

Length

350±2mm (13.78inch)

Width

167±2mm (6.57inch)

Height

179±2mm (7.05inch)

Total Height

T5: 186±2mm (7.32inch)

T9: 179±2mm (7.05inch)

Approx. Weight

21.5kg (47.4lbs)±4%

Terminal type

T5/T9

Internal resistance

(Fully charged, 25)

Approx. 5.5mΩ

Capacity affected by temperature (10HR)

40

102%

25

100%

0

85%

-15

65%

Self-discharge

(25)

3 month

Remaining Capacity: 91%

6 month

Remaining Capacity: 82%

12 month

Remaining Capacity: 65%

Nominal operating temperature

25±3(77℉±5)

Operating temperature range

Discharge

-15~50(5℉~122)

Charge

-10~50(14℉~122)

Storage

-20~50(-4℉~122)

Float charging voltage(25)

13.50 to 13.80V

Temperature compensation:

-18mV/

Cyclic charging voltage(25)

14.50 to 14.90V

Temperature compensation:

-30mV/

Maximum charging current

21A

Terminal material

Copper

Maximum discharge current

700A(5 sec.)

Designed floating life(20)

12 years

◆ Absorbent glass mat technology;

◆ Recognized by UL & CE;

◆ ABS container.












 
 
 Constant Current Discharge Characteristics (A, 25ºC)
F.V/TIME 5min 10min 15min 30min 60min 2h 3h 4h 5h 10h 20h
9.60V 8.74 5.52 4.37 2.44 1.50 0.82 0.59 0.47 0.40 0.22 0.117
9.90V 8.48 5.35 4.27 2.39 1.47 0.81 0.58 0.47 0.40 0.22 0.116
10.2V 8.13 5.13 4.11 2.32 1.44 0.81 0.58 0.46 0.39 0.22 0.116
10.5V 7.78 4.91 3.97 2.26 1.41 0.79 0.58 0.46 0.39 0.21 0.115
10.8V 7.34 4.64 3.76 2.18 1.36 0.77 0.56 0.45 0.38 0.21 0.113
Constant Power Discharge Characteristics (Watt, 25ºC)
F.V/TIME 5min 10min 15min 30min 60min 2h 3h 4h 5h 10h 20h
9.60V 97.5 62.3 49.8 27.9 17.3 9.56 6.97 5.59 4.76 2.61 1.40
9.90V 94.6 60.4 48.6 27.4 17.1 9.50 6.93 5.56 4.73 2.60 1.40
10.2V 90.7 57.9 46.8 26.5 16.6 9.42 6.88 5.52 4.70 2.58 1.39
10.5V 86.8 55.4 45.2 25.9 16.3 9.28 6.83 5.48 4.67 2.57 1.38
10.8V 81.9 52.3 42.8 24.9 15.8 9.04 6.63 5.31 4.53 2.52 1.35
Note: The above characteristics data can be obtained within three charge/discharge cycles.
 



International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval

BS approval


FP Series Battery General Features

  • Nonspillable
  • Sealed and Maintenance-free Operation
  • High Quality and High Reliability
  • Exceptional Deep Discharge Recovery
  • Low Self-discharge
  • Long Service Life
  • Solid Copper Terminals
  • Tank-formed Plates
  • Computer-aided Design and Manufacturing
  • UL, CE, VdS Approved

Typical Applications