Wind generation Reserve Battery 12V70AH Battery
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
Contact us now! Your partnership with FirstPower
will prove worthy of it.
can be used for just about every application, including: UPS Backup Systems, Alarm Systems, Fire Alarm Systems, Medical Equipment, Test Equipment, and much more.
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
70 Ah |
|
5HR(10.5V) |
61.5Ah |
||
1HR(9.60V) |
43.4Ah |
||
Dimension |
Length |
350±2mm (13.78inch) |
|
Width |
167±2mm (6.57inch) |
||
Height |
179±2mm (7.05inch) |
||
Total Height |
T5: 186±2mm (7.32inch) |
||
T9: 179±2mm (7.05inch) |
|||
Approx. Weight |
21.5kg (47.4lbs)±4% |
||
Terminal type |
T5/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 5.5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
21A |
||
Terminal material |
Copper |
||
Maximum discharge current |
700A(5 sec.) |
||
Designed floating life(20℃) |
12 years |
||
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25ºC)
Constant Power Discharge Characteristics (Watt, 25ºC)
F.V/TIME
5min
10min
15min
30min
60min
2h
3h
4h
5h
10h
20h
9.60V
8.74
5.52
4.37
2.44
1.50
0.82
0.59
0.47
0.40
0.22
0.117
9.90V
8.48
5.35
4.27
2.39
1.47
0.81
0.58
0.47
0.40
0.22
0.116
10.2V
8.13
5.13
4.11
2.32
1.44
0.81
0.58
0.46
0.39
0.22
0.116
10.5V
7.78
4.91
3.97
2.26
1.41
0.79
0.58
0.46
0.39
0.21
0.115
10.8V
7.34
4.64
3.76
2.18
1.36
0.77
0.56
0.45
0.38
0.21
0.113
Note: The above characteristics data can be obtained within three charge/discharge cycles.
F.V/TIME
5min
10min
15min
30min
60min
2h
3h
4h
5h
10h
20h
9.60V
97.5
62.3
49.8
27.9
17.3
9.56
6.97
5.59
4.76
2.61
1.40
9.90V
94.6
60.4
48.6
27.4
17.1
9.50
6.93
5.56
4.73
2.60
1.40
10.2V
90.7
57.9
46.8
26.5
16.6
9.42
6.88
5.52
4.70
2.58
1.39
10.5V
86.8
55.4
45.2
25.9
16.3
9.28
6.83
5.48
4.67
2.57
1.38
10.8V
81.9
52.3
42.8
24.9
15.8
9.04
6.63
5.31
4.53
2.52
1.35
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
FP Series Battery General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
- Telecommunication equipment
- Electronic instruments
- Fire alarm
- Security devices
- UPS power supply
- Emergency lighting
Related Keywords