Reserve Battery Wind Power Battery Factory 12V50AH
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
can be used for just about every application, including: UPS Backup Systems, Alarm Systems, Fire Alarm Systems, Medical Equipment, Test Equipment, and much more.
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
50Ah |
|
5HR(10.5V) |
43.7Ah |
||
1HR(9.60V) |
31Ah |
||
Dimension |
Length |
229±2mm (9.02inch) |
|
Width |
138±2mm (5.43inch) |
||
Height |
208±2mm (8.19inch) |
||
Total Height |
T5: 230±2mm (9.06inch) |
||
T9: 211±2mm (8.31inch) |
|||
Approx. Weight |
16kg (35.3lbs)±4% |
||
Terminal type |
T5/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 7.5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
15A |
||
Terminal material |
Copper |
||
Maximum discharge current |
500A(5 sec.) |
||
Designed floating life(20℃) |
12 years |
||
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
105 |
82.5 |
50.0 |
31.0 |
18.3 |
12.8 |
10.5 |
8.93 |
6.12 |
5.09 |
2.67 |
9.90V |
102 |
80.5 |
49.0 |
30.5 |
18.2 |
12.7 |
10.4 |
8.87 |
6.08 |
5.08 |
2.67 |
10.2V |
97.7 |
77.6 |
47.5 |
29.8 |
18.0 |
12.6 |
10.3 |
8.81 |
6.04 |
5.07 |
2.66 |
10.5V |
93.5 |
74.9 |
46.4 |
29.2 |
17.7 |
12.5 |
10.3 |
8.75 |
6.00 |
5.04 |
2.64 |
10.8V |
88.2 |
71.0 |
44.7 |
28.3 |
17.3 |
12.1 |
9.94 |
8.49 |
5.82 |
5.00 |
2.63 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
1134 |
906 |
561 |
353 |
212 |
150 |
123 |
105 |
72.7 |
60.8 |
32.1 |
9.90V |
1100 |
884 |
550 |
348 |
210 |
149 |
122 |
105 |
72.3 |
60.7 |
32.0 |
10.2V |
1055 |
851 |
533 |
339 |
208 |
148 |
121 |
104 |
71.8 |
60.5 |
31.9 |
10.5V |
1009 |
823 |
520 |
333 |
205 |
147 |
121 |
103 |
71.3 |
60.1 |
31.7 |
10.8V |
953 |
779 |
501 |
322 |
200 |
143 |
117 |
100 |
69.1 |
59.7 |
31.5 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
FP Series Battery General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
- Telecommunication equipment
- Electronic instruments
- Fire alarm
- Security devices
- UPS power supply
- Emergency lighting