Reserve GEL Battery 12V12AH SLI GEL Battery
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
Can be used for UPS Backup Systems, Alarm Systems, and much more. VRLA stands for valve-regulated lead-acid and is the designation for low-maintenance lead-acid rechargeable batteries. Because of their construction, VRLA batteries do not require regular addition of water to the cells. Reserve GEL Battery FPG12120,capacity :12V12Ah batteries is SLI GEL Battery.
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
20HR(10.5V) |
12Ah |
|
10HR(10.5V) |
10.7Ah |
||
1HR(9.60V) |
7.1Ah |
||
Dimension |
Length |
151±1.5mm (5.94inch) |
|
Width |
98±1mm (3.86inch) |
||
Height |
95±1mm (3.74inch) |
||
Total Height |
101±1mm (3.98inch) |
||
Approx. Weight |
3.5kg (7.71lbs)±5% |
||
Terminal type |
T2/T1 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 19mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
13.8 to 14.10V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
3.6A |
||
Terminal material |
Copper |
||
Maximum discharge current |
180A(5 sec.) |
||
Designed floating life(20℃) |
12years |
||
◆ Gelled electrolyte technology;
◆ PVC separator;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
24.5 |
20.2 |
12.0 |
7.1 |
4.12 |
2.91 |
2.35 |
1.93 |
1.29 |
1.08 |
0.61 |
9.90V |
23.7 |
19.7 |
11.7 |
7.0 |
4.09 |
2.90 |
2.34 |
1.92 |
1.28 |
1.08 |
0.61 |
10.2V |
22.8 |
19.0 |
11.4 |
6.8 |
4.06 |
2.88 |
2.32 |
1.91 |
1.27 |
1.07 |
0.60 |
10.5V |
21.8 |
18.3 |
11.1 |
6.7 |
4.00 |
2.86 |
2.30 |
1.90 |
1.26 |
1.07 |
0.60 |
10.8V |
20.6 |
17.3 |
10.7 |
6.4 |
3.89 |
2.77 |
2.23 |
1.84 |
1.22 |
1.05 |
0.59 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
276 |
230 |
137 |
81.8 |
48.2 |
34.6 |
28.0 |
23.1 |
15.4 |
13.0 |
7.31 |
9.90V |
268 |
224 |
135 |
80.6 |
47.9 |
34.4 |
27.8 |
23.0 |
15.3 |
13.0 |
7.28 |
10.2V |
257 |
216 |
130 |
78.6 |
47.5 |
34.2 |
27.6 |
22.8 |
15.2 |
12.9 |
7.24 |
10.5V |
246 |
209 |
127 |
77.0 |
46.7 |
33.9 |
27.4 |
22.6 |
15.1 |
12.8 |
7.20 |
10.8V |
232 |
198 |
123 |
74.6 |
45.6 |
32.9 |
26.6 |
22.0 |
14.7 |
12.6 |
7.06 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
FP Series Battery General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
- Telecommunication equipment
- Electronic instruments
- Fire alarm
- Security devices
- UPS power supply
- Emergency lighting
Related Keywords