Type C Rechargeable 12V Batteries
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LONG LIFE LFP12200KFT BATTERY
The LFP12200KFT BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.
ü High rate discharge construction.Aa Rechargeable Battery Price
ü Deep discharge recoverability.
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
200 Ah |
|
5HR(10.5V) |
175Ah |
||
1HR(9.60V) |
124Ah |
||
Dimension |
Length |
560±3mm (22.05inch) |
|
Width |
126±2mm (4.96inch) |
||
Height |
280±2mm (11.02inch) |
||
Total Height |
280±2mm (11.02inch) |
||
Approx. Weight |
58kg (127.8lbs)±4% |
||
Internal resistance (Fully charged, 25℃) |
Approx. 3.0mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
60A |
||
Terminal material |
Copper |
||
Maximum discharge current |
1300A(5 sec.) |
||
Designed floating life(20℃) |
15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
630 |
420 |
323 |
196 |
124 |
73.1 |
51.0 |
41.8 |
35.7 |
31.2 |
24.5 |
20.4 |
10.7 |
9.90V |
611 |
407 |
316 |
192 |
122 |
72.6 |
50.7 |
41.6 |
35.5 |
31.0 |
24.3 |
20.3 |
10.7 |
10.2V |
586 |
391 |
304 |
186 |
119 |
72.0 |
50.4 |
41.3 |
35.2 |
30.8 |
24.2 |
20.3 |
10.6 |
10.5V |
561 |
374 |
294 |
182 |
117 |
70.9 |
50.0 |
41.0 |
35.0 |
30.6 |
24.0 |
20.1 |
10.6 |
10.8V |
529 |
353 |
278 |
175 |
113 |
69.1 |
48.5 |
39.8 |
34.0 |
29.7 |
23.3 |
20.0 |
10.5 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
5min |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
6615 |
4536 |
3623 |
2199 |
1414 |
846 |
600 |
492 |
422 |
369 |
291 |
243 |
128 |
9.90V |
6417 |
4400 |
3536 |
2155 |
1392 |
841 |
596 |
489 |
419 |
367 |
289 |
243 |
128 |
10.2V |
6152 |
4218 |
3406 |
2089 |
1357 |
834 |
592 |
486 |
417 |
364 |
287 |
242 |
128 |
10.5V |
5887 |
4037 |
3290 |
2039 |
1330 |
821 |
588 |
482 |
414 |
362 |
285 |
240 |
127 |
10.8V |
5557 |
3810 |
3116 |
1964 |
1289 |
800 |
570 |
468 |
401 |
351 |
277 |
239 |
126 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.