LONG LIFE LFP12110FT BATTERY
The LFP12110FT BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.
ü High rate discharge construction.
ü Deep discharge recoverability.Rechargeable C Batteries 4 Pack
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
110 Ah |
|
5HR(10.5V) |
96Ah |
||
1HR(9.60V) |
68Ah |
||
Dimension |
Length |
395±2mm (15.55inch) |
|
Width |
110±2mm (4.33inch) |
||
Height |
286±2mm (11.26inch) |
||
Total Height |
286±2mm (11.26inch) |
||
Approx. Weight |
32.5kg (71.7lbs)±4% |
||
Terminal type |
T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
33A |
||
Terminal material |
Copper |
||
Maximum discharge current |
800A(5 sec.) |
||
Designed floating life(20℃) |
15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
178 |
108 |
68.2 |
40.2 |
28.1 |
23.0 |
19.6 |
17.2 |
13.5 |
11.2 |
5.88 |
9.90V |
174 |
106 |
67.2 |
40.0 |
27.9 |
22.9 |
19.5 |
17.1 |
13.4 |
11.2 |
5.87 |
10.2V |
167 |
102 |
65.5 |
39.6 |
27.7 |
22.7 |
19.4 |
16.9 |
13.3 |
11.1 |
5.85 |
10.5V |
162 |
99.9 |
64.2 |
39.0 |
27.5 |
22.6 |
19.3 |
16.8 |
13.2 |
11.1 |
5.82 |
10.8V |
153 |
96.3 |
62.2 |
38.0 |
26.7 |
21.9 |
18.7 |
16.3 |
12.8 |
11.0 |
5.78 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
1953 |
1210 |
777 |
465 |
330 |
270 |
232 |
203 |
160 |
134 |
70.5 |
9.90V |
1906 |
1185 |
766 |
463 |
328 |
269 |
231 |
202 |
159 |
133 |
70.4 |
10.2V |
1836 |
1149 |
746 |
459 |
326 |
267 |
229 |
200 |
158 |
133 |
70.2 |
10.5V |
1773 |
1121 |
732 |
452 |
323 |
265 |
228 |
199 |
157 |
132 |
69.8 |
10.8V |
1680 |
1080 |
709 |
440 |
314 |
257 |
221 |
193 |
152 |
131 |
69.3 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.