LONG LIFE LFP1240FT BATTERY
The LFP1240FT BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.Rechargeable D Batteries 8 Pack
ü High rate discharge construction.Battery Charger Rechargeable
ü Deep discharge recoverability.
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
pecifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
40 Ah |
|
5HR(10.5V) |
35Ah |
||
1HR(9.60V) |
24.8Ah |
||
Dimension |
Length |
277±2mm (10.91inch) |
|
Width |
106±2mm (4.17inch) |
||
Height |
221±2mm (8.70inch) |
||
Total Height |
221±2mm (8.70inch) |
||
Approx. Weight |
14kg (30.9lbs)±4% |
||
Terminal type |
T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 9.5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
12A |
||
Terminal material |
Copper |
||
Maximum discharge current |
400A(5 sec.) |
||
Designed floating life(20℃) |
15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
64.7 |
39.2 |
24.8 |
14.6 |
10.2 |
8.36 |
7.14 |
6.24 |
4.90 |
4.07 |
2.14 |
9.90V |
63.1 |
38.4 |
24.4 |
14.5 |
10.1 |
8.31 |
7.10 |
6.21 |
4.87 |
4.06 |
2.13 |
10.2V |
60.8 |
37.2 |
23.8 |
14.4 |
10.1 |
8.26 |
7.05 |
6.16 |
4.83 |
4.05 |
2.13 |
10.5V |
58.7 |
36.3 |
23.3 |
14.2 |
10.0 |
8.20 |
7.00 |
6.12 |
4.80 |
4.03 |
2.11 |
10.8V |
55.6 |
35.0 |
22.6 |
13.8 |
9.7 |
7.95 |
6.79 |
5.94 |
4.66 |
4.00 |
2.10 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
710 |
440 |
283 |
169 |
120 |
98.4 |
84.4 |
73.8 |
58.2 |
48.6 |
25.7 |
9.90V |
693 |
431 |
278 |
168 |
119 |
97.8 |
83.9 |
73.4 |
57.8 |
48.5 |
25.6 |
10.2V |
668 |
418 |
271 |
167 |
118 |
97.1 |
83.3 |
72.8 |
57.4 |
48.4 |
25.5 |
10.5V |
645 |
408 |
266 |
164 |
118 |
96.4 |
82.7 |
72.3 |
57.0 |
48.1 |
25.4 |
10.8V |
611 |
393 |
258 |
160 |
114 |
93.5 |
80.3 |
70.2 |
55.3 |
47.8 |
25.2 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.