Rechargeable Aa Battery Charger
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LONG LIFE LFP12100VL BATTERY
The LFP12100VL BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.
ü High rate discharge construction.Rechargeable Aa Battery Charger
ü Deep discharge recoverability.
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
100 Ah |
|
5HR(10.5V) |
87.5Ah |
||
1HR(9.60V) |
62.0Ah |
||
Dimension |
Length |
306mm±2 (12.05inch) |
|
Width |
169mm±2 (6.65inch) |
||
Height |
211mm±2 (8.31inch) |
||
Total Height |
T5: 233±2mm (9.17inch) |
||
T9: 214±2mm (8.43inch) |
|||
Approx. Weight |
29.5kg (65.02lbs)±4% |
||
Terminal type |
T5/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 5.5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
30A |
||
Terminal material |
Copper |
||
Maximum discharge current |
800A(5 sec.) |
||
Designed floating life(20℃) |
15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
204 |
162 |
98.0 |
62.0 |
36.5 |
25.5 |
20.9 |
17.9 |
12.2 |
10.2 |
5.34 |
9.90V |
198 |
158 |
96.0 |
61.1 |
36.3 |
25.4 |
20.8 |
17.7 |
12.2 |
10.2 |
5.33 |
10.2V |
189 |
152 |
93.1 |
59.5 |
36.0 |
25.2 |
20.6 |
17.6 |
12.1 |
10.1 |
5.32 |
10.5V |
181 |
147 |
90.8 |
58.3 |
35.5 |
25.0 |
20.5 |
17.5 |
12.0 |
10.1 |
5.29 |
10.8V |
171 |
139 |
87.5 |
56.5 |
34.6 |
24.3 |
19.9 |
17.0 |
11.6 |
10.0 |
5.25 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
2200 |
1775 |
1100 |
707 |
423 |
300 |
246 |
211 |
145 |
122 |
64.1 |
9.90V |
2134 |
1733 |
1078 |
696 |
421 |
298 |
244 |
210 |
145 |
121 |
64.0 |
10.2V |
2046 |
1669 |
1045 |
679 |
417 |
296 |
243 |
208 |
144 |
121 |
63.8 |
10.5V |
1958 |
1612 |
1019 |
665 |
411 |
294 |
241 |
207 |
143 |
120 |
63.4 |
10.8V |
1848 |
1527 |
982 |
645 |
400 |
285 |
234 |
201 |
138 |
119 |
63.0 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.