Aaa Lithium Ion Rechargeable Batteries
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LONG LIFE LFP1242L BATTERY
The LFP1242L BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.
ü High rate discharge construction.Aaa Lithium Ion Rechargeable Batteries
ü Deep discharge recoverability.
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
42 Ah |
|
5HR(10.5V) |
37Ah |
||
1HR(9.60V) |
24.8Ah |
||
Dimension |
Length |
197±2mm (7.76inch) |
|
Width |
165±2mm (6.50inch) |
||
Height |
170±2mm (6.69inch) |
||
Total Height |
170±2mm (6.69inch) |
||
Approx. Weight |
14kg (30.9lbs)±4% |
||
Terminal type |
T4/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 8.5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
12.6A |
||
Terminal material |
Copper |
||
Maximum discharge current |
420A(5 sec.) |
||
Designed floating life(20℃) |
15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
86 |
68 |
41 |
24.8 |
15.3 |
10.7 |
8.8 |
7.5 |
5.1 |
4.3 |
2.24 |
9.90V |
83 |
66 |
40 |
24.4 |
15.3 |
10.6 |
8.7 |
7.5 |
5.1 |
4.3 |
2.24 |
10.2V |
80 |
64 |
39 |
23.8 |
15.1 |
10.6 |
8.7 |
7.4 |
5.1 |
4.3 |
2.23 |
10.5V |
76 |
62 |
38.2 |
23.3 |
14.9 |
10.5 |
8.6 |
7.4 |
5.0 |
4.2 |
2.22 |
10.8V |
72 |
58 |
36.8 |
22.6 |
14.5 |
10.2 |
8.4 |
7.1 |
4.9 |
4.2 |
2.21 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
10min |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
8h |
10h |
20h |
9.60V |
924 |
746 |
462 |
297 |
178 |
126 |
103 |
89 |
61 |
51 |
26.9 |
9.90V |
896 |
728 |
453 |
292 |
177 |
125 |
103 |
88 |
61 |
51 |
26.9 |
10.2V |
859 |
701 |
439 |
285 |
175 |
124 |
102 |
87 |
60 |
51 |
26.8 |
10.5V |
822 |
677 |
428 |
279 |
172 |
123 |
101 |
87 |
60 |
50 |
26.6 |
10.8V |
776 |
641 |
412 |
271 |
168 |
120 |
98 |
84 |
58 |
50 |
26.5 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.