
The Best Rechargeable Batteries
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
Specifications
Nominal Voltage |
12 V |
||
Capacity (25℃) |
10HR(10.8V) |
105 Ah |
|
5HR(10.5V) |
92Ah |
||
1HR(9.60V) |
65Ah |
||
Dimension |
Length |
395±2mm (15.55inch) |
|
Width |
110±2mm (4.33inch) |
||
Height |
286±2mm (11.26inch) |
||
Total Height |
286±2mm (11.26inch) |
||
Approx. Weight |
32.5kg (71.7lbs)±4% |
||
Terminal type |
T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 5mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~70℃(5℉~158℉) |
|
Charge |
-10℃~70℃(14℉~158℉) |
||
Storage |
-20℃~70℃(-4℉~158℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
31.5A |
||
Terminal material |
Copper |
||
Maximum discharge current |
800A(5 sec.) |
||
Designed floating life(20℃) |
13~15 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
170 |
103 |
65.1 |
38.4 |
26.8 |
22.0 |
18.7 |
16.4 |
12.9 |
10.7 |
5.61 |
9.90V |
166 |
101 |
64.1 |
38.1 |
26.6 |
21.8 |
18.6 |
16.3 |
12.8 |
10.7 |
5.60 |
10.2V |
160 |
97.8 |
62.5 |
37.8 |
26.4 |
21.7 |
18.5 |
16.2 |
12.7 |
10.6 |
5.58 |
10.5V |
154 |
95.4 |
61.3 |
37.2 |
26.3 |
21.5 |
18.4 |
16.1 |
12.6 |
10.6 |
5.55 |
10.8V |
146 |
91.9 |
59.4 |
36.3 |
25.5 |
20.9 |
17.8 |
15.6 |
12.2 |
10.5 |
5.51 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
9.60V |
1864 |
1155 |
742 |
444 |
315 |
258 |
222 |
194 |
153 |
128 |
67.3 |
9.90V |
1819 |
1131 |
731 |
442 |
313 |
257 |
220 |
193 |
152 |
127 |
67.2 |
10.2V |
1752 |
1097 |
712 |
438 |
311 |
255 |
219 |
191 |
151 |
127 |
67.0 |
10.5V |
1693 |
1070 |
698 |
431 |
309 |
253 |
217 |
190 |
150 |
126 |
66.6 |
10.8V |
1603 |
1031 |
677 |
420 |
299 |
246 |
211 |
184 |
145 |
125 |
66.2 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications
Fire alarm systems
Solar lighting equipment
Outdoor telecommunication equipment
Related Keywords