Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
FP690HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use.
* High rate discharge construction.
* ISO9001, 14001, OHSMS 18001 certified.* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
6 V |
||
Number of cell |
3 cells |
||
Capacity(20HR, 25℃) |
9 Ah |
||
Capacity(15min.rate, 25℃) |
34 Watts/cell |
||
Dimension |
Length |
151±1.5mm (5.94inch) |
|
Width |
34±1mm (1.34inch) |
||
Height |
94±1mm (3.70inch) |
||
Total Height |
100±1mm (3.94inch) |
||
Approx. Weight |
1.35kg (2.98lbs)±5% |
||
Terminal type |
T1/T2 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 8mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
6.80 to 6.90V Temperature compensation: -9mV/℃ |
||
Cyclic charging voltage(25℃) |
7.25 to 7.45V Temperature compensation: -15mV/℃ |
||
Maximum charging current |
2.7A |
||
Terminal material |
Copper |
||
Maximum discharge current |
135A(5 sec.) |
||
Designed floating life(20℃) |
3~5 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
es';font-family:'Times New Roman';font-size:9.0000pt;mso-font-kerning:1.0000pt;" >ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
3h |
5h |
10h |
20h |
1.60V/cell |
37.3 |
22.8 |
18.0 |
14.3 |
9.87 |
7.08 |
5.59 |
2.34 |
1.61 |
0.87 |
0.466 |
1.65V/cell |
36.1 |
22.1 |
17.5 |
13.9 |
9.68 |
6.94 |
5.51 |
2.33 |
1.60 |
0.86 |
0.464 |
1.67V/cell |
35.6 |
21.8 |
17.3 |
13.7 |
9.56 |
6.85 |
5.45 |
2.32 |
1.59 |
0.86 |
0.463 |
1.70V/cell |
34.7 |
21.2 |
16.9 |
13.4 |
9.38 |
6.73 |
5.37 |
2.31 |
1.59 |
0.86 |
0.462 |
1.75V/cell |
33.2 |
20.3 |
16.3 |
12.9 |
9.15 |
6.56 |
5.26 |
2.30 |
1.58 |
0.86 |
0.459 |
1.80V/cell |
31.3 |
19.2 |
15.5 |
12.3 |
8.82 |
6.32 |
5.10 |
2.23 |
1.53 |
0.84 |
0.450 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
3h |
5h |
10h |
20h |
1.60V/cell |
71.1 |
45.8 |
35.4 |
28.1 |
19.5 |
13.9 |
11.0 |
4.68 |
3.21 |
1.74 |
0.93 |
1.65V/cell |
69.7 |
44.7 |
34.6 |
27.4 |
19.1 |
13.7 |
10.8 |
4.65 |
3.19 |
1.73 |
0.93 |
1.67V/cell |
68.8 |
44.3 |
34.0 |
27.0 |
18.8 |
13.5 |
10.7 |
4.64 |
3.18 |
1.73 |
0.93 |
1.70V/cell |
67.5 |
43.5 |
33.3 |
26.4 |
18.5 |
13.2 |
10.6 |
4.62 |
3.17 |
1.72 |
0.92 |
1.75V/cell |
65.6 |
41.9 |
32.2 |
25.5 |
18.0 |
12.9 |
10.4 |
4.59 |
3.15 |
1.71 |
0.92 |
1.80V/cell |
63.5 |
40.9 |
30.5 |
24.1 |
17.4 |
12.5 |
10.0 |
4.45 |
3.06 |
1.68 |
0.90 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System
Related Keywords