FP670HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use.
* High rate discharge construction.
* ISO9001, 14001, OHSMS 18001 certified.* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.Lithium D Cell Batteries Rechargeable
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
6 V |
||
Number of cell |
3 cells |
||
Capacity(20HR, 25℃) |
7 Ah |
||
Capacity(15min.rate, 25℃) |
31 Watts/cell |
||
Dimension |
Length |
151±1.5mm (5.94inch) |
|
Width |
34±1mm (1.34inch) |
||
Height |
94±1mm (3.70inch) |
||
Total Height |
100±1mm (3.94inch) |
||
Approx. Weight |
1.28kg (2.82lbs)±5% |
||
Terminal type |
T1/T2 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 9mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
6.80 to 6.90V Temperature compensation: -9mV/℃ |
||
Cyclic charging voltage(25℃) |
7.25 to 7.45V Temperature compensation: -15mV/℃ |
||
Maximum charging current |
2.1A |
||
Terminal material |
Copper |
||
Maximum discharge current |
105A(5 sec.) |
||
Designed floating life(20℃) |
3~5 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
es';font-family:'Times New Roman';font-size:9.0000pt;mso-font-kerning:1.0000pt;" >ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
3h |
5h |
10h |
20h |
1.60V/cell |
33.9 |
20.8 |
16.4 |
13.0 |
8.99 |
6.45 |
5.09 |
1.82 |
1.25 |
0.67 |
0.362 |
1.65V/cell |
32.9 |
20.2 |
16.0 |
12.7 |
8.81 |
6.32 |
5.01 |
1.81 |
1.24 |
0.67 |
0.361 |
1.67V/cell |
32.4 |
19.9 |
15.7 |
12.5 |
8.71 |
6.24 |
4.96 |
1.80 |
1.24 |
0.67 |
0.360 |
1.70V/cell |
31.6 |
19.3 |
15.4 |
12.2 |
8.54 |
6.13 |
4.89 |
1.80 |
1.23 |
0.67 |
0.359 |
1.75V/cell |
30.2 |
18.5 |
14.9 |
11.8 |
8.34 |
5.98 |
4.79 |
1.79 |
1.23 |
0.67 |
0.357 |
1.80V/cell |
28.5 |
17.5 |
14.1 |
11.2 |
8.03 |
5.76 |
4.64 |
1.73 |
1.19 |
0.65 |
0.350 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
3h |
5h |
10h |
20h |
1.60V/cell |
62.5 |
39.6 |
32.3 |
25.6 |
17.7 |
12.7 |
10.0 |
3.64 |
2.50 |
1.35 |
0.72 |
1.65V/cell |
60.5 |
38.1 |
31.5 |
25.0 |
17.4 |
12.4 |
9.88 |
3.62 |
2.48 |
1.34 |
0.72 |
1.67V/cell |
59.6 |
37.3 |
31.0 |
24.5 |
17.1 |
12.3 |
9.78 |
3.61 |
2.48 |
1.34 |
0.72 |
1.70V/cell |
58.2 |
36.5 |
30.3 |
24.0 |
16.8 |
12.1 |
9.63 |
3.59 |
2.47 |
1.34 |
0.72 |
1.75V/cell |
57.0 |
35.1 |
29.3 |
23.2 |
16.4 |
11.8 |
9.44 |
3.57 |
2.45 |
1.33 |
0.71 |
1.80V/cell |
54.2 |
33.3 |
27.7 |
22.0 |
15.8 |
11.3 |
9.15 |
3.46 |
2.38 |
1.30 |
0.70 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System
Related Keywords