
CE Certificate Waveform Finger pulse oximeter FS20A
- Delivery Time:
- 5 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Specifications Waveform Finger pulse oximeter
1. Beautiful appearance
2. High Measurement Accuracy
3. Good performance in Motion,low perfus
CE Certificate Waveform Finger pulse oximeter FS20A Digital fingertip pulse oximeter 1. portable , lightwight
2. highly accurate ,
3. Aoto power off without finger
4. beep alarm Instructions Principle of the Apollo FS20A Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology, the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc. Major Features Integrated with SpO2 probe and processing display module; Color OLED display; Small in volume,light in weight and convenient in carrying; Operation of the product is simple ,low power consumption; SpO2 value , Pulse rate value , bar graph, battery voltage display; voltage indication: voltage indicator always appears; Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 8 seconds if the finger falls out of probe. Main performance Display Mode: Red/Blue/Yellow three color OLED display SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%:±2% ,Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±3%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than 25mA Voltage: DC 2.6V~3.6V Power Supply: 1.5V (AAA size) alkaline batteries × 2 Battery working hour: The minimum continually work time is 24 hours ,theoretical number is 30 hours. Safety Type: Interior Battery,BF Type Accessories
a hanging rope
a user manual Physical Identity Dimension: 62(L) × 35(W) × 31(H) mm
Weight: About 50g (with the batteries)
1. Beautiful appearance
2. High Measurement Accuracy
3. Good performance in Motion,low perfus
CE Certificate Waveform Finger pulse oximeter FS20A Digital fingertip pulse oximeter 1. portable , lightwight
2. highly accurate ,
3. Aoto power off without finger
4. beep alarm Instructions Principle of the Apollo FS20A Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology, the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc. Major Features Integrated with SpO2 probe and processing display module; Color OLED display; Small in volume,light in weight and convenient in carrying; Operation of the product is simple ,low power consumption; SpO2 value , Pulse rate value , bar graph, battery voltage display; voltage indication: voltage indicator always appears; Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 8 seconds if the finger falls out of probe. Main performance Display Mode: Red/Blue/Yellow three color OLED display SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%:±2% ,Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±3%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than 25mA Voltage: DC 2.6V~3.6V Power Supply: 1.5V (AAA size) alkaline batteries × 2 Battery working hour: The minimum continually work time is 24 hours ,theoretical number is 30 hours. Safety Type: Interior Battery,BF Type Accessories
a hanging rope
a user manual Physical Identity Dimension: 62(L) × 35(W) × 31(H) mm
Weight: About 50g (with the batteries)




Related Keywords
Related Keywords
You May Also Like
You May Also Like