Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Specifications 1 Small Offline UPS
2.Cold start ,AVR Function
3.used for computer , non critcial load
4.RS232 USB PORT
RBK 12V 24V Small Offline UPS 600VA 1000VA 1500VA Feature .1.wide voltage range ,AVR function 2.cold start function 3.intelligent CPU control 4.SMD technology to save space 5.Both audible and lamp alarm functions 6.intelligent battery management 7.RS-232 communication inter face and USB(optional)
2.Cold start ,AVR Function
3.used for computer , non critcial load
4.RS232 USB PORT
RBK 12V 24V Small Offline UPS 600VA 1000VA 1500VA Feature .1.wide voltage range ,AVR function 2.cold start function 3.intelligent CPU control 4.SMD technology to save space 5.Both audible and lamp alarm functions 6.intelligent battery management 7.RS-232 communication inter face and USB(optional)
Model No. | 600N | 800N | 1000N | 1500N | |
Power capacity (VAW) | 600VA/360W | 800VA/480W | 1000VA/600VA | 1500VA/900W | |
Input | |||||
nominal voltage | 120VAC/230VAC | ||||
Voltage range | 85-140VAC/140-300VAC | ||||
Frequency Range | 50hz or 60HZ±5HZ(auto sensing) | ||||
output | |||||
Voltage | 120VAC/230VAC±10% | ||||
Frequency | Sync to input (line mode)50HZor60HZ±0.1%(battery mode) | ||||
Waveform type | Modified sinewave | ||||
Auto Transfer | after overload recovering 100%load | ||||
Crest power | 3 times of rating | ||||
Power factor | >0.6 | ||||
Batteries | |||||
Type | Maintenance -free sealed Lead-Acid battery | ||||
Nominal DC voltage | 12VDC | 24VDC | |||
Eastimated Runtime (minutes )100wload | 20 | 29 | 45 | 75 | |
Recharging time | 8hours to 90% of full capacity | ||||
transfer time | <6 ms (standard mode0 | ||||
Protection | overload ,low battery ,surge (customer-made) | ||||
Led Display | Operation mode(online -green,battery-yellow,fault-red) | ||||
Audible Alarm | battery mode ,low battery ,overload ,battery repalcement,fault | ||||
Output Sockets | NEMA5-15 (or IEC320×2pcs) | NEMA5-15 (or IEC320×2or4pcs) | |||
Communications management | |||||
interface port | RS-232/USB(Customer-made) | ||||
Enviromental | |||||
Operation enviroment | 0-40°C | ||||
Relative humidity | 0-95%(non-condensing | ||||
Audible Noise | <40db | ||||
Physical | |||||
Netweight | 6 | 6.5 | 13.8 | 14.2 | |
dimension,D×W×H | 315*85*139(MM) | 338*123*185(mm) | |||
Application | computer center in power plant or converting station |