Product Description
Specifications SOLAR CHARGER CONTROLLER,Solar charger controller is a 40 amp 12/24 voltage Maximum Power Point Tracking (MPPT) photovoltaic PV

SOLAR CHARGER CONTROLLER   Solar charger controller is a 40 amp 12/24 voltage Maximum Power Point Tracking (MPPT) photovoltaic (PV) battery charge controller. Through the use of MPPT technology, Solar charger controller can increase charge current up to 30% or more compared to conventional controllers.   12V/24V Solar Charge Controller FeaturesHigh converting efficiency higher than 97% for minimizing energy loss Build-in MPPT tracker for optimizing the power transformation Reversed current protection for preventing equipment damage Automatic battery temperature compensation for long-term reliability Capable of selecting different charging mode for various type of batteries Capable of connecting additional DC load for wider applications Three stage charge control system (bulk, absorption, and float mode) with temperature compensation LED indicators display charge status in real time Pulse Width Modulation (PWM) topology combined with a multi-stage charge control algorithm leads to superior charging and enhanced battery performance

MODEL

SMS-40A

Rated Voltage

12/24 VDC

Rated charge current

40A

Load current

15A

Input voltage range

15-55VDC

Max. PV open circuit array voltage

55VDC

Typical idle consumption

At idle < 10mA

Overload protection (DC load)

2.0*Inom>5s

1.5*Inom >20s

1.25*Inom temperature controlled

Bulk charge

14.6V(default)

29.2V(default)

Floating charge

13.4V(default)

26.8V(default)

Equalization charge

14.0V(default)

28.0V(default)

Over charge disconnection

14.8V

29.6V

Over charge recovery

13.6V

27.2V

Over discharge disconnection

10.8 V (default)

21.6V(default)

Over discharge reconnection

12.3V

24.6V

Temperature compensation

-13.2mV/

-26.4mV/

Lead acid battery settings

Adjustable

NiCad battery settings

Adjustable

Load control mode

1.       Low Voltage Reconnect (LVR): Adjustable

2. Low Voltage Disconnect (LVD): Automatic disconnection

3. Reconnection: Includes warning flash before disconnect and reconnection

Low voltage reconnect

12.0-14.0 Vdc

24.0-28.0 Vdc

Low voltage disconnect

10.5-12.5 Vdc

21.0-25.0 Vdc

Ambient temperature

0-40(full load)  4060(de-rating)

Altitude

Operating 5000 m, Non-Operating 16000 m

Protection class

IP21

Battery temperature sensor

BTS - optional remote battery temperature sensor for increased charging precision

Terminal size (fine/single wire)

#8 AWG