Santak online ups 110v 220v 50hz 60hz
- Delivery Time:
- 20 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Specifications Santak online ups
true on-line double conversion technology with advanced microprocessor control 110V/220V
RACK-MOUNT ONLINE UPS BS Series adopts to servers, data centers, critical network devices, sensitive electronic equipment, Telecom and so on. Key Features True on-line double conversion technology with advanced microprocessor control Wide input voltage range Zero transfer time Protection against all type of power problems Self test while start of the UPS Site wiring fault warning On-battery power-on function Smart RS232 communication interface Intelligent slot available Sealed lead-acid, maintenance free battery Technical Specifications
true on-line double conversion technology with advanced microprocessor control 110V/220V
RACK-MOUNT ONLINE UPS BS Series adopts to servers, data centers, critical network devices, sensitive electronic equipment, Telecom and so on. Key Features True on-line double conversion technology with advanced microprocessor control Wide input voltage range Zero transfer time Protection against all type of power problems Self test while start of the UPS Site wiring fault warning On-battery power-on function Smart RS232 communication interface Intelligent slot available Sealed lead-acid, maintenance free battery Technical Specifications
Product Series | Rack Mount 1~6kVA | ||||
Model | BS1KR | BS2KR | BS3KR | BS6KR | |
Rated Power | VA/W | 1kVA/0.7kW | 2kVA/1.4kW | 3kVA/2.1kW | 6kVA/4.2kW |
Input | Nominal Voltage | 110V/220VAC | |||
Voltage Range | 60~138 Vac 115 ~ 300VAC | 176 ~ 276VAC | |||
Frequency Range | 46 ~ 54Hz(default), user adjustable within 40~60Hz | 46 ~ 54Hz | |||
Power Factor | 0.97 | 0.98 | |||
Connection | IEC320-10A inlet | IEC320-16A inlet | Terminal Block | ||
Output | Voltage | 110V/220VAC ± 2% | 110V/220VAC ± 1% | ||
Frequency | 46~54Hz or 50Hz ± 0.2Hz (Line mode) 50Hz ± 0.2Hz ( Battery mode) | 46~54Hz (Line mode) 50Hz ± 0.05Hz ( Battery mode) | |||
Waveform | Sine Wave | ||||
Overload Capability | 108%~150% for 30 sec., ³150% for 300 ms | 105%~130% for 10 min., ³130% for 1 min. | |||
Current Crest Ratio | 3:1 | ||||
Bypass | Automatic Transfer | on overload and UPS failure | |||
Before UPS Power-on | Default NO, user adjustable to YES | Yes | |||
Output Connections | IEC320 -10A * 4 | IEC320-10A * 4 | IEC320-10A and Terminal Block | IEC320-10A * 4 and Terminal Block | |
Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | Zero | |||
LED indicators | Status | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | |||
Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | ||||
Communications | RS-232 Serial Interface | ||||
Intelligent Slot; OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) | |||||
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | ||||
Environmental | Operating Temperature | 0 ~ 40°C | |||
Operating Humidity | 20 ~ 90% non-condensing | ||||
Main Unit | Net Weight (Kg) | 15.0 | 9.6 | 10.0 | 18.3 |
Dimensions (W x D x H) mm | 482 x 420 x 88 (2U) | 482.6 x 600 x 130 (3U) | |||
Battery Pack | Type | Internal Batteries | External Battery Pack | ||
Nominal DC Voltage | 36VDC | 96VDC | 240VDC | ||
Backup Time (Full load) | 5 min | 9 min (with 1 BP) | 5 min (with 1 BP) | 7 min (with 1 BP) | |
Net Weight (Kg) | -- | 26.0 | 64.2 | ||
Dimensions (W x D x H) mm | -- | 482 x 420 x 88 (2U) | 482.6 x 600 x 130 (3U) |