NEW Conventional Fire Alarm Control System Conventional Fire Alarm Control Panel 4 zones panel PY-CK1004
- Delivery Time:
- 3 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
NEW Conventional Fire Alarm Control System Conventional Fire Alarm Control Panel 4 zones panel PY-CK1004 conventional fire alarm panel FEATURES: * Four to Sixteen Style B (Class B) Initiating Device Circuits (IDCs).
* All zones accept two-wire smoke detectors and any normally-open contact devices.
* Zones 1 - 16 configured as general alarm zones.
* All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.
* Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).
* NACs may be programmed: Silenceable. Non-Silenceable.
* Auto-Silence (program 5 to 20 minutes).
* 1.25 amps of NAC power.
* 3.0 amps of total system power.
* Alarm, Trouble and Supervisory, Form-C relay standard.
* 24-volt operation.
* Resettable four-wire smoke detector power @ 500 mA.
* Non-resettable power @ 500 mA.
* Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).
* One-man walk-test programmable for silent or audible test.
* Disable/Enable control per IDC.
* Reverse polarity protection.
* Control buttons:
Mode/Test/ACK (Acknowledge) Alarm Silence/Reset
* LED indicators:
AC Power(green & yellow LED)
Fire Alarm(red LED)
Trouble(yellow LED)
Supervisory(yellow LED)
Signal Silence(yellow LED)
Battery Power(green & yellow LED)
Zone Disable(yellow LED)
NAC Fault(yellow LED)
NAC Disable(yellow LED)
Zone Alarm(one for each zone) (red LED)
Zone Trouble(one for each zone) (yellow LED) conventional fire alarm panel SPECIFICATIONS: * AC POWER: 220 VAC, 50 Hz, 2.0 amps.
* Wire size: minimum 14 AWG (2.0 mm²) with 600-volt insulation.
* BATTERY: Sealed lead-acid batteries only.
* Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge.
* Maximum battery charger capacity: 18AH battery. NOTE: two 4AH batteries can be housed in the cabinet. Larger batteries require a separate battery box.
Our Services 1. Original High Quality Products: All of our products are Original High Quality Products, We have strict quality control system, they are 100% tested before factory, we don’t sell products with only low prices. 2. Professional Technical Team: We can offer comprehensive solution for your projects We can offer detailed pre-sales requirements analysis and guide. We can offer professional remotely technical support for problems 3. Flexible Customization: We can customize software, firmware for customers requirements. 4. OEM,ODM service: We can design and produce machines with your own logo. 5. Good Service: We treat clients as good friend. 6. Special offers: We have special offers for long-term cooperation clients
* All zones accept two-wire smoke detectors and any normally-open contact devices.
* Zones 1 - 16 configured as general alarm zones.
* All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.
* Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).
* NACs may be programmed: Silenceable. Non-Silenceable.
* Auto-Silence (program 5 to 20 minutes).
* 1.25 amps of NAC power.
* 3.0 amps of total system power.
* Alarm, Trouble and Supervisory, Form-C relay standard.
* 24-volt operation.
* Resettable four-wire smoke detector power @ 500 mA.
* Non-resettable power @ 500 mA.
* Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).
* One-man walk-test programmable for silent or audible test.
* Disable/Enable control per IDC.
* Reverse polarity protection.
* Control buttons:
Mode/Test/ACK (Acknowledge) Alarm Silence/Reset
* LED indicators:
AC Power(green & yellow LED)
Fire Alarm(red LED)
Trouble(yellow LED)
Supervisory(yellow LED)
Signal Silence(yellow LED)
Battery Power(green & yellow LED)
Zone Disable(yellow LED)
NAC Fault(yellow LED)
NAC Disable(yellow LED)
Zone Alarm(one for each zone) (red LED)
Zone Trouble(one for each zone) (yellow LED) conventional fire alarm panel SPECIFICATIONS: * AC POWER: 220 VAC, 50 Hz, 2.0 amps.
* Wire size: minimum 14 AWG (2.0 mm²) with 600-volt insulation.
* BATTERY: Sealed lead-acid batteries only.
* Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge.
* Maximum battery charger capacity: 18AH battery. NOTE: two 4AH batteries can be housed in the cabinet. Larger batteries require a separate battery box.