
conventional smoke alarm control panel to detector the fire and smoke, CK1008
- Delivery Time:
- 1 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Specifications 1, conventional smoke alarm control panel
2, CK1004 fire smoke alarm
3, control fire smoke alarm
Conventional smoke Alarm Control Panel The CK1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective CK1000 Series can be used in a variety of low- to mid-sized applications. Features of fire alarm control panel 1.Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept two-wire smoke detectors and any normally-open contact devices. Two Supervisory Input with DC12V output, ideal to connect security alarm devices. 2.Three General Alarm, Trouble and Supervisory,Form A Relay Output. 3.One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs), NACs may be programmed: Silenceable or Non-Silenceable. 4.3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output. 5.Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode. 6.RS485 Communication Port (optional). 7.Automatic/Manual mode can be programmed. Disable/Enable control per Zone (IDC) can be programmed. 8.Disable/Enable Sound Output(NACs) can be programmed. 9.Zones Input :4,8,16 zones Modules for user to select, each zone can connect max.25 conventional detectors
2, CK1004 fire smoke alarm
3, control fire smoke alarm
Conventional smoke Alarm Control Panel The CK1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective CK1000 Series can be used in a variety of low- to mid-sized applications. Features of fire alarm control panel 1.Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept two-wire smoke detectors and any normally-open contact devices. Two Supervisory Input with DC12V output, ideal to connect security alarm devices. 2.Three General Alarm, Trouble and Supervisory,Form A Relay Output. 3.One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs), NACs may be programmed: Silenceable or Non-Silenceable. 4.3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output. 5.Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode. 6.RS485 Communication Port (optional). 7.Automatic/Manual mode can be programmed. Disable/Enable control per Zone (IDC) can be programmed. 8.Disable/Enable Sound Output(NACs) can be programmed. 9.Zones Input :4,8,16 zones Modules for user to select, each zone can connect max.25 conventional detectors
Related Keywords
Related Keywords
You May Also Like
You May Also Like