Product Description
Introduction:
F009 Is a non-contact proximity card and password access control touch access one machine, simple to use, reliable performance, mainly the following functions:
1, touch buttons, appearance more beautiful, longer life;
2, proximity card to open the door, inductive card and password, the password to open the door three ways to open the door;
3, a group WG26 interface, external WG read head; or set WG26 output of the machine when WG26 reader;
4, a set of relay dry contact output and a PUSH (low) output;
5, a set of door button interface; doorbell interface;
6, normally open, normally closed three backlight mode automatically;
7, has a the tamper function and safe operation mode;
1.2 The main parameters
Operating voltage : DC 12V ± 10%
Operating current: <100mA
Dimensions: 120mm × 78mm × 22mm
Weight: 130g
Ambient temperature:-10 °C -70 °C
Relative humidity: 20% -80%
User capacity:1,000
Card Type: EM card or Mifare one card
Read Range:EM :1-15CM, MF1 :1-7CM
Programming operation
The basic steps of 4.1 programming operation
The first step to enter the program state:
Programming password # input # in standby mode, buzzer shall sound, red light, access control machine to enter the programming mode.
The second step programming operation:
Enter the appropriate programming command (see 4.2 programming operation details).
The third step is to exit the programming operation:
Any time in the state of programming press * to exit the programming mode; 2 minutes without any operation in the programming mode will automatically exit programming state.
Describe 4.2 programming commands
"0" Kin to modify the programming password:
To enter 0 new programming password # password # Repeat new programming
Note: The programming password can be 3 to 6 digits.
"1" health, increase card to open the door "type of user
Enter a user ID reader #
Note 1: 0001 to 9999 four-digit user number, the same below.
Note 2: when you add users, each successfully added a user, the buzzer sounding out; operation buzzer shall sound,
Indicates that the input is invalid, invalid reasons may be: (1) user ID repeat, (2) the card number already exists, (3) storage area is full, the same below.
Note 3: For continuous add multi-user cards, immediately after reading the first card read the card to increase later (per read a card, the user
Number will automatically sliding scale), press "#" to exit after the end of the card.
"2" health, increase the "the password door" type user
Enter the user ID to open the door password #
Note: to open the door, the password can be 3 to 6 digits. A door password is also occupied by a user capacity.
"3" health, increase card + password to open the door "type of user
Enter 3 user ID reader with the card PIN codes corresponding #
"4" key, delete users
A, enter 400000 # to delete all users
B, enter the user delete the card reader card reader # 41
C, input 42 user # delete the corresponding number of users
D, input the 43 manually enter the card number # delete the user of the card number (10 digits of the card number for the the induction card on the left)
"5" key, modify the unlock signal output time
Enter the 5 XX #
Unlock signal output Note: "XX" indicates the number of seconds, the value of 00 to 99, where 00 represents the the instant output (0.2 seconds).
"6" key, set to open the door mode
Enter 610 # card to open the door
Enter the # 611 card and password
Enter 612 # card or password to open the door
To as WG26 read head use enter 613 # native
"7" key, set the security mode
Enter 700 # turn off security features
Enter the security features in 701 #
Note: opportunities for one of the following access control security features enabled, the deadlock five minutes:
A ten consecutive times read invalid card
B, ten times in a row to enter the wrong PIN codes
C, in the mode of the card and password, read the valid card four consecutive enter the wrong PIN codes
"8" key, set tamper switch, backlight mode and restore the factory settings
Enter 800 # turn off the the Tamper alarm switch function
Enter 801 # open the Tamper alarm switch function
Enter 802 # backlight mode normally open
Enter 803 # backlight mode normally closed
Input 804 # backlight mode for automatic (no operation off the backlight automatically after 15 seconds)
Enter 899 # to restore factory settings
Note: After initialization operation, access control machine parameters fully restored to factory settings (see 3.1), the user data is not lost.
4.3 Restore Factory Settings
Step 1: Disconnect the power supply, 2 and 3 feet of the the S1 pin on the jumper cap jump.
Step two: power, continuous sounding buzzer.
The third step: to disconnect the power to put the the S1 pin on the jumper the cap jump back to the first and second legs.
Step Four: power, buzzer sounding loudly successful initialization, access control machine into standby.
Note: After initialization operation, access control machine parameters fully restored to factory settings (see 3.1), the user data is not lost.
Five users open the door operation
5.1 credit card to open the door:
When the door mode is set to one of the card to open the door "or" cards or password to open the door "access control machine in standby, hold a valid card credit card Access control, buzzer shall sound, the green light, then The unlock signal is output, the door is open.
5.2 password to open the door:
When the door mode is set to "cards or password to open the door, access control machine in standby mode, enter PIN codes # buzzer shall sound, the green light, then unlock signal output, the door opened.
5.3 card and password:
When the door mode is set to "card and password access control machine in the standby state, the first credit card (when the buzzer sounding bang, green flash), corresponding to the door with the card and then enter password # buzzer short beep is heard, the green light is lit, then unlock signal output, the door opened.
Note: credit card or enter a password, if the buzzer short beep three times, said the card or password for invalid user can not open the door.
5.4 modify the corresponding PIN codes and cards:
When the door mode is set to "card and password, the user credit card then enter the door password successfully open the door after 5 seconds, press and hold the" well "until the green flash, then enter the new password # Repeat New Password # buzzer blew loudly, and open the door with the card corresponding password successfully modified. IMAGE:

F009 Is a non-contact proximity card and password access control touch access one machine, simple to use, reliable performance, mainly the following functions:
1, touch buttons, appearance more beautiful, longer life;
2, proximity card to open the door, inductive card and password, the password to open the door three ways to open the door;
3, a group WG26 interface, external WG read head; or set WG26 output of the machine when WG26 reader;
4, a set of relay dry contact output and a PUSH (low) output;
5, a set of door button interface; doorbell interface;
6, normally open, normally closed three backlight mode automatically;
7, has a the tamper function and safe operation mode;
1.2 The main parameters
Operating voltage : DC 12V ± 10%
Operating current: <100mA
Dimensions: 120mm × 78mm × 22mm
Weight: 130g
Ambient temperature:-10 °C -70 °C
Relative humidity: 20% -80%
User capacity:1,000
Card Type: EM card or Mifare one card
Read Range:EM :1-15CM, MF1 :1-7CM
Programming operation
The basic steps of 4.1 programming operation
The first step to enter the program state:
Programming password # input # in standby mode, buzzer shall sound, red light, access control machine to enter the programming mode.
The second step programming operation:
Enter the appropriate programming command (see 4.2 programming operation details).
The third step is to exit the programming operation:
Any time in the state of programming press * to exit the programming mode; 2 minutes without any operation in the programming mode will automatically exit programming state.
Describe 4.2 programming commands
"0" Kin to modify the programming password:
To enter 0 new programming password # password # Repeat new programming
Note: The programming password can be 3 to 6 digits.
"1" health, increase card to open the door "type of user
Enter a user ID reader #
Note 1: 0001 to 9999 four-digit user number, the same below.
Note 2: when you add users, each successfully added a user, the buzzer sounding out; operation buzzer shall sound,
Indicates that the input is invalid, invalid reasons may be: (1) user ID repeat, (2) the card number already exists, (3) storage area is full, the same below.
Note 3: For continuous add multi-user cards, immediately after reading the first card read the card to increase later (per read a card, the user
Number will automatically sliding scale), press "#" to exit after the end of the card.
"2" health, increase the "the password door" type user
Enter the user ID to open the door password #
Note: to open the door, the password can be 3 to 6 digits. A door password is also occupied by a user capacity.
"3" health, increase card + password to open the door "type of user
Enter 3 user ID reader with the card PIN codes corresponding #
"4" key, delete users
A, enter 400000 # to delete all users
B, enter the user delete the card reader card reader # 41
C, input 42 user # delete the corresponding number of users
D, input the 43 manually enter the card number # delete the user of the card number (10 digits of the card number for the the induction card on the left)
"5" key, modify the unlock signal output time
Enter the 5 XX #
Unlock signal output Note: "XX" indicates the number of seconds, the value of 00 to 99, where 00 represents the the instant output (0.2 seconds).
"6" key, set to open the door mode
Enter 610 # card to open the door
Enter the # 611 card and password
Enter 612 # card or password to open the door
To as WG26 read head use enter 613 # native
"7" key, set the security mode
Enter 700 # turn off security features
Enter the security features in 701 #
Note: opportunities for one of the following access control security features enabled, the deadlock five minutes:
A ten consecutive times read invalid card
B, ten times in a row to enter the wrong PIN codes
C, in the mode of the card and password, read the valid card four consecutive enter the wrong PIN codes
"8" key, set tamper switch, backlight mode and restore the factory settings
Enter 800 # turn off the the Tamper alarm switch function
Enter 801 # open the Tamper alarm switch function
Enter 802 # backlight mode normally open
Enter 803 # backlight mode normally closed
Input 804 # backlight mode for automatic (no operation off the backlight automatically after 15 seconds)
Enter 899 # to restore factory settings
Note: After initialization operation, access control machine parameters fully restored to factory settings (see 3.1), the user data is not lost.
4.3 Restore Factory Settings
Step 1: Disconnect the power supply, 2 and 3 feet of the the S1 pin on the jumper cap jump.
Step two: power, continuous sounding buzzer.
The third step: to disconnect the power to put the the S1 pin on the jumper the cap jump back to the first and second legs.
Step Four: power, buzzer sounding loudly successful initialization, access control machine into standby.
Note: After initialization operation, access control machine parameters fully restored to factory settings (see 3.1), the user data is not lost.
Five users open the door operation
5.1 credit card to open the door:
When the door mode is set to one of the card to open the door "or" cards or password to open the door "access control machine in standby, hold a valid card credit card Access control, buzzer shall sound, the green light, then The unlock signal is output, the door is open.
5.2 password to open the door:
When the door mode is set to "cards or password to open the door, access control machine in standby mode, enter PIN codes # buzzer shall sound, the green light, then unlock signal output, the door opened.
5.3 card and password:
When the door mode is set to "card and password access control machine in the standby state, the first credit card (when the buzzer sounding bang, green flash), corresponding to the door with the card and then enter password # buzzer short beep is heard, the green light is lit, then unlock signal output, the door opened.
Note: credit card or enter a password, if the buzzer short beep three times, said the card or password for invalid user can not open the door.
5.4 modify the corresponding PIN codes and cards:
When the door mode is set to "card and password, the user credit card then enter the door password successfully open the door after 5 seconds, press and hold the" well "until the green flash, then enter the new password # Repeat New Password # buzzer blew loudly, and open the door with the card corresponding password successfully modified. IMAGE: