Battery backup led down lights 12v / 6v rechargeable
- Delivery Time:
- 10 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Battery backup led down lights 12v / 6v rechargeable Emergency Conversion Kit = Emergency Inverter + Ni-CD/Ni-MH/Li-ion Battery Pack + Aluminum Box/Metal Box + Other Accessaries
How to choose the emergency conversion kit for your project ? 1, Pls confirm what kind of l luminaires it is, such as your lighting is LED tube, LED panel,LED downlight, CFL, or Fluorescent etc.What’s more,pls let us know the power of luminaires (W). 2, Pls let us know your local mains power. 3, Once confirm your luminaires is led downlight and led panel, pls let us know the driver's parameters of your luminaires 4, It’s better to tell us what is your requirement about the emergency brightness you need and how long emergency duration when mains power failure.
Instruction manual Product name: LED light with external led driver Product highlights 1. According to EN60598; EN 55015; CE; ROHS 2. Deep discharge protection 3. Operation time (discharge):2hours 4. Using 70℃ high temperature Ni-Cd battery which can be installed into led light fitting 5. LED monitor is red in charging mode. It’ll automatically change into green after fully charging. 6. Test button which can transit normal mode into emergency mode Specification Voltage: AC220-240 V 50/60Hz or 100-240 V 50/60Hz Current: 0.07A Rate power:6.5W(charging) Power factor:0.65 Battery charging: 24hours (rechargeable, suggest to charge more than 24hours for first use) Charging current: 300MA Discharge current:: 0.90A Terminate discharge voltage of battery:10V Output: DC 15-36V 300mA Suitable light source: LED tube(with external led driver); LED panel light Battery specification: Ni-Cd12V 2000MAh HT (High temperature) Environment temperature: -10…+55℃ Highest surface temperature: 70℃ LED charge monitoring: charging(green) Test switch: switch between emergency and normal lighting function, should have normally open switch
The Schematic Diagram for Universal LED Emergency Conversion Kit
Application Range :
Application Guide :
1.1.Install the unit according to wiring diagram, any improper wiring may lead to permanent damage to the unit;
1.2.Normal AC mains supply, the inverter allows the battery pack charging, trickle charge to maintain battery performance. Sudden interruption of the mains AC, then the inverter converts DC battery powered to ensure that lighting and security; 1.3.Inverter with multiple protection functions: charge protection, discharge protection, short circuit protection;
1.4.To ensure maximum performance of the builtin battery, please fully charge the unit for 24hours after first installation; To extend battery life, please contact with EVEN TECHNOLOGY and make sure charge the battery at least one time every three months. 1.5.Don’t install top of the high temperature objects. Please ensure that the operating ambient temperature is below 50ºC, and maximum case temperature (tc) not exceeding 80ºC; 1.6.Do not operate this unit beyond the operating supply range;
1.7. In normal use, the battery can be done 1000 charge/discharge cycles
1.8. Inverter life is more than 2 years
1.9.Please make sure not wrong connect the mains AC, or else will broken the inverter.
1.10. If experience any problem during use, please contact with EVEN TECHNOLOGY for help. Company Information Battery backup led down lights 12v / 6v rechargeable
Packaging & Shipping
Welcome to Even Technology and thank you so much for your visiting.Any feedback from you is our big moving.Thank you for your supporting !


10W LED Power (1hrs) | Battery Pack :12V AA 1000mAh Ni-CD +Combined driver and inverter |
12V AA 1000mAh Ni-MH +Combined driver and inverter | |
11.1V 18650 Li-ion Battery + Inverter | |
10W LED Power (2hrs) | Battery Pack :12V SC 2000mAh Ni-CD +Combined driver and inverter |
12V SC 2000mAh Ni-MH +Combined driver and inverter | |
11.1V 18650 Li-ion Battery + Inverter | |
10W LED Power(3hrs) | Battery Pack :12V C 3000mAh Ni-CD +Combined driver and inverter |
12V C 3000mAh Ni-MH +Combined driver and inverter | |
11.1V 18650 Li-ion Battery + Inverter | |
Inverter Voltage | AC85-265/50-60Hz |
Emergency Brightness | 10%-100% |
Inverter Output Power | Total Power |
Battery Dimensions | (Single Battery Cell) AA Size:14.1*49mm SC Size:42*22mm C Size:50*25mm D Size:60*33mm F Size : 90*33mm |
Application Range | LED Tube/Panel/Downlight/2D Lamp/Ceiling Lamp/Fluorescent ect. |



1.1.Install the unit according to wiring diagram, any improper wiring may lead to permanent damage to the unit;
1.2.Normal AC mains supply, the inverter allows the battery pack charging, trickle charge to maintain battery performance. Sudden interruption of the mains AC, then the inverter converts DC battery powered to ensure that lighting and security; 1.3.Inverter with multiple protection functions: charge protection, discharge protection, short circuit protection;
1.4.To ensure maximum performance of the builtin battery, please fully charge the unit for 24hours after first installation; To extend battery life, please contact with EVEN TECHNOLOGY and make sure charge the battery at least one time every three months. 1.5.Don’t install top of the high temperature objects. Please ensure that the operating ambient temperature is below 50ºC, and maximum case temperature (tc) not exceeding 80ºC; 1.6.Do not operate this unit beyond the operating supply range;
1.7. In normal use, the battery can be done 1000 charge/discharge cycles
1.8. Inverter life is more than 2 years
1.9.Please make sure not wrong connect the mains AC, or else will broken the inverter.
1.10. If experience any problem during use, please contact with EVEN TECHNOLOGY for help. Company Information Battery backup led down lights 12v / 6v rechargeable