
Gas leak detector wireless home alarm system
- Delivery Time:
- 10 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|
Product Description
Product Description
Specifications *MCU processing adopted
*Execute criterion:EN50194
*Independent Gas Detector with back up battery
*Wall mounted
Gas leak detector wireless home alarm system model: JKD-812
Specification *Gas Detector with back up battery
*Execute criterion:GB15322;EN50194;UL1484
*Independent Gas Detector with back up battery *Semiconductor sensor
*Operating voltage: 85-265V AC; Wall mounted;
*Alarm output: Sound& LED Flash alarm;
*Alarm level: 10% ±5% LEL.
*MCU processing adopted,SMT adopted,good stability
*Malfunction auto-check indicator
*Dimension: 118.5*82*43mm .
*Execute criterion:GB15322;EN50194;UL1484 TEST: To test the installed detector while using independently, you can give some gas around in distance of 5cm to the gas convection holes by using un-ignition lighter. Testing frequently may result in reducing the sensitivity of the detector. The alarm density of gas is set according with the criteria of GB15322.2-2005.The Detector will stop alarm and resume to the detecting state while the gas density reduced to lower than the alarm level. NORMAL MAINTENANCE: Suggestion: the user must brush and clean the gas convection holes with a little cleanser every three months, and must retest the Detector after cleaning for preventing the cleanser into the Detector. EMERGENCY ALARM TREATMENT: The Detector alarms while the gas density in air exceed the alarm level. The relative treatments as below:
1. Shut down the tube valve right away.
2. Open the window and make the air flow rapidly.
3. Extinguish all fire sources and do not use anything can make fire, e.g. lighters, matches, etc.
4. Avoiding open or close the power all kinds of electric equipment.
5. Check the reason of gas leaking, and notice the relative departments and professional persons in time Not exactly what you are looking for? Tell us what you want!
*Execute criterion:EN50194
*Independent Gas Detector with back up battery
*Wall mounted
Gas leak detector wireless home alarm system model: JKD-812

*Execute criterion:GB15322;EN50194;UL1484
*Independent Gas Detector with back up battery *Semiconductor sensor
*Operating voltage: 85-265V AC; Wall mounted;
*Alarm output: Sound& LED Flash alarm;
*Alarm level: 10% ±5% LEL.
*MCU processing adopted,SMT adopted,good stability
*Malfunction auto-check indicator
*Dimension: 118.5*82*43mm .
*Execute criterion:GB15322;EN50194;UL1484 TEST: To test the installed detector while using independently, you can give some gas around in distance of 5cm to the gas convection holes by using un-ignition lighter. Testing frequently may result in reducing the sensitivity of the detector. The alarm density of gas is set according with the criteria of GB15322.2-2005.The Detector will stop alarm and resume to the detecting state while the gas density reduced to lower than the alarm level. NORMAL MAINTENANCE: Suggestion: the user must brush and clean the gas convection holes with a little cleanser every three months, and must retest the Detector after cleaning for preventing the cleanser into the Detector. EMERGENCY ALARM TREATMENT: The Detector alarms while the gas density in air exceed the alarm level. The relative treatments as below:
1. Shut down the tube valve right away.
2. Open the window and make the air flow rapidly.
3. Extinguish all fire sources and do not use anything can make fire, e.g. lighters, matches, etc.
4. Avoiding open or close the power all kinds of electric equipment.
5. Check the reason of gas leaking, and notice the relative departments and professional persons in time Not exactly what you are looking for? Tell us what you want!
Related Keywords
Related Keywords