Auto reset gas leak detector sensor
  • Auto reset gas leak detector sensor
Auto reset gas leak detector sensor

Auto reset gas leak detector sensor

Delivery Time:
10 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong, China (Mainland)
Product Description
Product Description
Specifications Gas And Carbon Monoxide Detector

Auto-reset after alarm;can work with electrovalve/exhaust fan

Available for Natural gas, LPG

Auto reset gas leak detector sensor Model:JKD-806                                                                                                                                                                                                                                           PRODUCT INTRODUCTION:       The product is wall mounted gas detector with high stability, It is used for detecting leaking gas. Advanced semiconductor sensor is adopted to ensure high stability and long life. It is convenient for mounting. The product is suitable for the safety of residential house, villas, hotels, markets, boarding house etc.       MAIN FEATURE:        High Reliability Sensor   Auto Reset after Alarm   MCU Processing Adopted Auto Detect Sensor Failture   Induced GAS/LPG and Natural Gas   SMT Design, High Stability  
TECHNIQUE DETAILS:       Operating voltage:  220V AC 
Rated power: ≤3W (220V AC power supply)
Warm-up time: 3-5 minutes
Alarm level: 10% LEL of Natural gas
Alarm indicator:  Corresponding Red LED flash 
Malfunction indicator: Yellow LED on & Beeper long-buzz
Alarm sound: ≥85dB (within 1 meter)
Operating temperature: -10 to 50
Environmental humidity: ≤95% RH (No congelation)
Installation mode: Wall mounted
Alarm output: Relay output /sound & flash alarm
Dimension: 115*72*41mm       TEST:       To test the installed detector while using independently, you can give some gas around in distance of 5cm to the gas convection holes by using un-ignition lighter.   Testing frequently may result in reducing the sensitivity of the detector. The alarm density of gas is set according with the criteria of GB15322.2-2005.The Detector will stop alarm and resume to the detecting state while the gas density reduced to lower than the alarm level.  
NORMAL MAINTENANCE:       Suggestion: the user must brush and clean the gas convection holes with a little cleanser every three months, and must retest the Detector after cleaning for preventing the cleanser into the Detector.       EMERGENCY ALARM TREATMENT:       The Detector alarms while the gas density in air exceed the alarm level. The relative treatments as below:
1. Shut down the tube valve right away.
2. Open the window and make the air flow rapidly.
3. Extinguish all fire sources and do not use anything can make fire, e.g. lighters, matches, etc.
4. Avoiding open or close the power all kinds of electric equipment.
5. Check the reason of gas leaking, and notice the relative departments and professional persons in time.          