A60 surface/interfacial tensiometer
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Shanghai, China (Mainland) |
---|
1. in stock.
2.precision measurement.
3.good quality
A60 surface/interfacial goniometer

1 | Weighing Sensor | (1) Measuring Range | 0-999.999mN/m |
(2) Resolution | 0.001mN/m | ||
(3) Weighing Accuracy | 0.04mN/m | ||
(4) Absolute Error | ±0.2mN/m (Reference secondary distilled water) | ||
(5) Weighing Capacity | 220g | ||
(6) Weighing Readability | 0.1mg | ||
(7) Data Update Speed | 23 data/s | ||
(8) Data Processing | Double-chip processor | ||
(9) Zeroing Method | One-key zeroing with presetting functions | ||
2 | Sample Stage Control | (1) Lifting Range | 0-50mm |
(2) Lifting Accuracy | Travel resolution:0.007μm; Repetitive positioning: 0.5μm | ||
(3) Control of Lifting Speed | Variable speed | ||
(4) Control Mode | Software-controlled via USB port for better compatibility | ||
(5)Positioning Readout Mode | Read by software encoder | ||
3 | Communication Port | USB2.0 port can be directly connected to laptops, without compatibility of Rs232 | |
4 | Temperature Readout (Relevant accessories should be optional purchased) | (1) Temp. Sensor | Digital semiconductor temperature sensor made in U.S.A. |
(2) Temp. Calibration | Self-calibration | ||
(3) Accuracy | 0.01°C | ||
(4) Readout Mode | Automatically read by software |
1 | Measuring Method | 3 methods, includes: - Modified Wilhelmy plate method - Classical Wilhelmy plate method - DuNoüy ring method |
2 | Measuring Mode | Both automatic and manual mode in measurement of surface / interface tension |
3 | Standardized Measurement Templates (Optional purchased or customized) | Various standardized measurement templates are available from USA KINO: -Measurement of surface tension and equilibrium surface tension as well as estimation of equilibrium time for surfactant. -Measurement of surface tension and equilibrium surface tension as well as estimation of equilibrium time for medium-high viscosity sample. -High-precision surface & interface tension measurement of pure liquid with fixed surface tension -Interface tension measurement, especially for plate-upward state in interface tension measurement. -Measurement of interface tension between monomolecular film and water, etc. |
4 | Calibration | Self-calibration of platinum plate & platinum ring and weighing sensor calibration |
5 | Pre-wetting Function | Providing human-oriented pre-wetting function |
6 | Interface Detection | Detection of interface of liquid-gas/liquid-liquid automatically by software |
7 | Density Correction | Density correction with preset function for measurement of interface tension |
8 | Buoyancy Correction | 3 kinds of buoyancy correction modes, professional FK correction factor |
9 | Database Management | Real-time graph and storage, query of measured data and data Excel exportable |
1 | Dimension | 390L * 500W * 470H mm |
2 | Weight | 32Kg |
3 | Power Supply | AC 100-240 50/60Hz |
4 | Power | 40W |
Model | A601 | A601S |
Standard Components | 1, one mainframe 2, one piece of platinum plate 3, two sets of sample vessels 4, one alcohol lamp 5, one tweezer 6, one data cable 7, one CAST®1.0 CD and relevant driver disk 8, one set of standard weights 9, one weight of 100 mg 10, one user manual | 1, one mainframe 2, one piece of platinum plate 3, two sets of sample vessels 4, one alcohol lamp 5, one tweezer 6, one data cable 7, one CAST®1.0 CD and relevant driver disk 8, one set of standard weights 9, one weight of 100 mg 10, one user manual 11, one piece of platinum ring 12, one set of temperature sensors 13, one set of portable control terminal |
Accessories | 1, platinum ring 2, temperature sensors 3, thermo-stating sample chamber 4, computer | 1, thermo-stating sample chamber |
Related Keywords