
Impulse Voltage Generator Applicable for testing of 220kv -
- Min. Order:
- 1
- Min. Order:
- 1
- Delivery Time:
- 30 Days
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Beijing, China |
---|
Impulse Voltage Generator Applicable for testing of 220kv -7200 kV
CDYH impulse voltage generator is designed for applications of high voltage level, high capacity and high load requirements. It is mainly used to test the ability of HV apparatus withstanding voltage peaks (220kv and more voltage level transformer, switch, cable, inductor, insulator etc). It is designed for applications of research and routine test.
Main features:
Product |
H type impulse voltage generator |
|
Type |
CDYH |
|
Structure |
H type |
1 steel frame consisting of 4 flanges and 2 external capacitors for each stage, multi-stage design, easy reconfiguration and maintenance, stable structure. |
Functions |
It is used to test the ability of HV apparatus withstanding voltage peaks (transformer, switch, cable, inductor, insulator etc) |
|
Advantages |
Good appearance |
As shown in the photo |
Easy modulation |
Manually wire wound resistors; compact design, low inductance, easier for lightning simulation |
|
High synchronization rate |
Unique synchronization technology; synchronization range≥20%, malfunction rate≤1% |
|
Ease of operation |
Resistors connected by spring contacts for easy and quick installation and reconfiguration |
|
High output efficiency |
Lightning wave efficiency≥90% (idle); switching wave efficiency≥70% (approx. 3000pF total load) |
|
High mobility |
Air cushion transportation system available for easy displacement . |
|
Stable performance |
Long-time operation at a voltage lower than 80% of rated voltage |
|
Performance |
Lightning |
Up to 6000kV standard lightning wave |
Chopped wave |
Up to 4200kV chopped wave |
|
Switching impulse |
Up to 4800kV switching impulse |
|
Oscillatory wave |
15 0% and more |
|
Special waves |
Waves of 500/100 μ S front time and extra-long half-peak time |
|
Integrated configuration of impulse generator and charging unit |
||
Symmetric bilateral charging unit |
||
Charging unit with automatic grounding and polarity reversal |
||
Capacitor with safety grounding device |
||
Encapsulated spark gaps with filtered air-flow |
||
The world’s leading performance on parameters |
Specifications:
Type |
Rated voltage(kV) |
Total energy(kJ) |
Capacitance (μ F) |
Stage voltage (kV) |
NO. of stages(n) |
Height(m) |
CDYH1400KV |
1400 |
70~210 |
0.071~0.21 |
200 |
7 |
6.0 |
CDYH1600KV |
1600 |
80~240 |
0.063~0.188 |
200 |
8 |
6.6 |
CDYH1800KV |
1800 |
90~270 |
0.056~0.167 |
200 |
9 |
7.3 |
CDYH2000KV |
2000 |
100~300 |
0.05~0.15 |
200 |
10 |
7.8 |
CDYH2200KV |
2200 |
110~330 |
0.045~0.136 |
200 |
11 |
8.4 |
CDYH2400KV |
2400 |
120~360 |
0.042~0.125 |
200 |
12 |
9.3 |
CDYH2800KV |
2800 |
140~420 |
0.036~0.107 |
200 |
14 |
10.8 |
CDYH3000KV |
3000 |
150~450 |
0.033~0.1 |
200 |
15 |
11.4 |
CDYH3200KV |
3200 |
160~480 |
0.031~0.094 |
200 |
16 |
12.0 |
CDYH3600KV |
3600 |
180~540 |
0.028~0.083 |
200 |
18 |
13.4 |
CDYH4000KV |
4000 |
200~600 |
0.025~0.075 |
200 |
20 |
14.8 |
CDYH4200KV |
4200 |
200~600 |
0.023~0.068 |
200 |
21 |
15.5 |
CDYH4800KV |
4800 |
240~720 |
0.021~0.063 |
200 |
23 |
17.3 |
CDYH6000KV |
6000 |
450~1350 |
0.025~0.075 |
300 |
20 |
21.3 |
CDYH7200KV |
7200 |
540~1620 |
0.021~0.063 |
300 |
24 |
25.4 |
CHYH-W series
4200kV impulse voltage generator at 4300m altitude
China’s first 7200kV voltage level impulse voltage generator
CDYH-W impulse voltage generator is designed for outdoor applications of high voltage level, high capacity, high load requirements and wind-proof, rain-proof and anti-UV properties for extreme ambient conditions. It is mainly used to test the ability of outdoor HV apparatus withstanding voltage peaks (medium and high voltage transformer, switch, cable, inductor, insulator etc). It is designed for applicationsof research and routine test.
Main features:
Product |
H type outdoor impulse voltage generator |
|
Type |
CDYH-W |
|
Structure |
H-W type |
1 steel frameconsisting of 4 flanges and 2 capacitors in parallel for each stage, multi-stage design, easy and quick installation, reconfiguration and maintenance; stable structure; glass wall shield or protective cylinder for outdoor operation |
Functions |
It is used to test the ability of outdoor HV apparatus to withstand voltage peaks |
|
Advantages |
Good appearance |
As shown in the photo |
Easy modulation |
Manually wire wound resistors; compact design, low inductance, easier for lightning simulation |
|
High synchronization rate |
Unique synchronization technology; synchronization range≥20%, malfunction rate≤1% |
|
Ease of operation |
Resistors connected by spring contacts for easy and quick installation and reconfiguration; internal ladder and operating platform at every second or third stage for easy and safe operation |
|
High output efficiency |
Lightning wave efficiency≥90% (idle); switching wave efficiency≥70% (approx. 3000pF total load) |
|
Mobility |
Immobile due to outdoor fixed installation |
|
Stable performance |
Long-time operation at a voltage lower than 80% of rated voltage |
|
Performance |
Lightning |
Up to 6000kV standard lightning wave |
Chopped wave |
Up to 4200kV chopped wave |
|
Switching impulse |
Up to 4800kV switching impulse |
|
Special waves |
Waves of 500/100 μ S front time and extra-long half-peak time |
|
The impulse voltage generator and the charging unit are integrated. |
||
Symmetric bilateral charging unit |
||
Charging unit with automatic grounding and polarity reversal; generator with grounding devices for safe and reliable operation |
||
Encapsulated spark gaps with filtered air-flow |
||
Wind-proof, rain-proof, anti-UV properties for extreme ambient conditions |
||
World’s leading technologies with parameters |
[CDYH-k series]
CDYH-k impulse voltage generator is an on-site ready-to-install model for convenient transport and quick on-site installation. It is mainly used to test the ability of outdoor or field HV apparatus withstanding voltage peaks (transformer, switch, cable, inductor, insulator etc). It is designed for applications of research and routine test.
Testing site at 5000m altitude
Main features:
Product |
H-k type impulse voltage generator |
|
Type |
CDYH-K |
|
Structure |
module type |
1 steel frame consisting of 4 flanges and 2 external capacitors for each stage, 3-stage per module, modules stored in containers for easy transportation, installation and reconfiguration |
Functions |
It is used to test the ability of outdoor or field HV apparatus to withstand voltage peaks |
|
Advantages |
Good appearance |
As shown in the photo |
Easy transportation |
Modules stored in containers for easy transportation, installation and reconfiguration |
|
Easy modulation |
Manually wire wound resistors; compact design, low inductance, easier for lightning simulation |
|
High synchronization rate |
Unique synchronization technology; synchronization range≥20%, malfunction rate≤1% |
|
Ease of operation |
Resistors connected by spring contacts for easy and quick installation and reconfiguration |
|
High output efficiency |
Lightning wave efficiency≥90% (idle); switching wave efficiency≥70% (approx. 3000pF total load) |
|
Stable performance |
Long-time operation at a voltage lower than 80% of rated voltage |
|
Performance |
Oscillatory lightning wave |
Output efficiency = 150% and more |
Oscillatory switching impulse |
Output efficiency = 150% and more |
|
The impulse voltage generator and the charging unit are integrated. |
||
Symmetric bilateral charging unit |
||
Charging unit with automatic grounding and polarity reversal |
||
Capacitor with safety grounding device |
||
Encapsulated spark gaps with filtered air-flow |
||
China’s first of its kind; indispensible for GIS on-site delivery tests |
For detail specifiction, Please contact us.
Application fields
Transformer manufacture, high voltage switch, electrical cable and wire, arrester insulator, electrical testing institute, weather industry, petroleum industry, scientific research and teaching and so on.