Shenzhen AMP Xunli Technology Co., Ltd.
Shenzhen AMP Xunli Technology Co., Ltd.
fluke wire cat6 utp 4pairs cable
  • fluke wire cat6 utp 4pairs cable
fluke wire cat6 utp 4pairs cable

fluke wire cat6 utp 4pairs cable

  • USD45
    ≥100 Set/Sets
Payment Type:
L/C, T/T
Incoterm:
FOB
Min. Order:
100 Set/Sets
Min. Order:
100 Set/Sets
Delivery Time:
15 Days
Transportation:
Ocean
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong, China
Productivity: 5000 boxes/ month
Payment Type: L/C,T/T
Incoterm: FOB
Certificate: UL
Transportation: Ocean
Product Description
Product Description
The AMPXL BOX UTP CAT5e cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs).
The AMPXL cable comes from the latest generation of UTP twisted pair cables. Its external diameter has been reduced to 5.0 mm, which considerably facilitates insertion of the cable into ducts and pipes. Special insulation material makes it easier to attach RJ-45 connectors.
Main features of AMPXL UTP cat 5e cable:
highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
parameters far exceeding the requirements for Category 5+ twisted pair cables
preliminary quality control of materials and thorough tests of the final product,
meter markers, deviation less than 0.5%,
solid wires of 0.50 mm diameter (24 AWG),
wire insulation made of homogeneous, colored PE; outer diameter: 0.88 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
insulated wires twisted in pairs of 1.8 mm diameter,
pairs twisted together, outer diameter of ca. 4.0 mm,
sheath made of gray/ blue PVC, of 5.0 mm diameter.
The AMPXL UTP cat 5e LAN cable is manufactured in compliance with:
IEC 61156-6, ISO/IEC 11801, ANSI/TIA/EIA-568-B, yd/t1019-2001 standards.
The AMPXL UTP cat 5e cable can be used in a wide temperature range: -20°C...+70°C, and installed between 0°C and +50°C. The minimum bending radius factor (radius to diameter ratio) is 8.
Specifications
Name AMPXL Cat
UTP 5e
Code 500
Structure
Wires solid copper conductors
Ø 0.50 mm (24 AWG)
Wire insulation HDPE
Sheath PVC (gray/ blue)
Outer diameter [mm] 5.0 ±0.3
Copper content [kg/km] 14.9
Weight [kg/km] 28.5
Electrical parameters
Impedance [Ω] 100 ±15
Capacitance of any transmission path at 1kHz [nF/km] 50 ±1
Nominal Velocity of Propagation (NVP) [%] 67
Resistance of any transmission path [Ω/km] ≤ 188
Asymmetry in capacitance of transmission paths to the ground [pF/km] ≤ 1600
Insulation resistance [MΩ/km] > 500
Installation and operation
Operating temperature range [°C] -20...+70
Operating humidity range [%] 0...100
Installation temperature range [°C] 0...+50
Minimum bending radius [radius to diameter ratio] >8

The results of the measurements of the U/UTP kat. 5e cable conducted by the
National Institute of Telecommunications in Shenzhen, China
Pair resistance and resistance asymmetry testing.
Cable Pair Wire Wire resistance [Ω/km] Resistance asymmetry [%]
UTP cat. 5e 1 a 92,726 0,35
b 93,054
2 a 94,662 0,34
b 94,982
3 a 96,228 0,55
b 96,755
4 a 96,107 0,39
b 95,733
Required - - <150 ≤3,0

Effective capacitance and capacitance asymmetry testing.
Cable Pair Effective capacitance [nF/km] Capacitance asymmetry [pF/km]
UTP cat. 5e 1 47,35 77
2 44,87 132
3 45,71 36
4 46,70 5
Required - - ≤1600

Insulation testing.
Cable Pair Wire Insulation resistance [MΩ/km]
UTP cat. 5e 1 a 8,8·104
b 1,2·105
2 a 9,0·104
b 1,6·105
3 a 8,1·104
b 2,0·105
4 a 7,5·104
b 1,1·105
Required - - ≥50

Tests of electric strength of insulation.
Test method Test voltage VAC
Applied (passed) Required
Voltage applied between connected in parallel all a wires and all b wires 1000 1000

End-to-end attenuation testing.
Cable Pair Effective attenuation [dB]
UTP cat. 5e 1 22,9
2 22,8
3 21,5
4 21,2
Required - ≤24,9

Near End Cross Talk (NEXT) testing.
Cable Pair to pair NEXT [dB]
UTP cat. 5e 1 - 2 43,5
1 - 3 47,9
1 - 4 45,3
2 - 3 44,9
2 - 4 47,8
3 - 4 41,4
Required - ≥34,0

Return loss testing.
Cable Pair Return loss [dB]
UTP cat. 5e 1 20,8
2 21,2
3 20,9
4 19,9
Required - ≥19,4

Total Near End Cross Talk (PS-NEXT) testing.
Cable Pair PS-NEXT [dB]
UTP cat. 5e 1 36,94
2 33,93
3 33,63
4 35,44
Required - ≥31,0