Portable Multiparameter Vet Use Patient Monitor Medical Equipment with CE Veterinary for Dog and Cat
- Payment Type:
- Telegraphic Transfer in Advance (Advance TT, T/T)
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | Telegraphic Transfer in Advance (Advance TT, T/T) |
---|
Product Description
Product Description
- ECG
- Lead mode: I/II/III/AVR/AVL/AVF/V
- Gain: X0.25/X0.5/X1/X2
- Heart rate:
- Adult: 15 to 300bpm
- Neonatal: 15 to 350bpm
- Resolution: 1bpm
- Accuracy: ±1%
- ST measurement range: -2.0, ±2.0mV
- Accuracy: ±10%
- Pacemaker: supported
- Sweep speed: 12.5/25/50mm/second
- Bandwidth:
- Diagnostic: 0.05 to 130Hz
- Monitor: 0.5 to 40Hz
- Surgery: 1 to 20Hz
- SPO2
- Measure range: 0 to 100%
- Resolution: 1%
- Accuracy: 2% (70 to 100%)
- Pulse rate: 20 to 250bpm
- Resolution: 1bpm
- Accuracy: ±3bpm
- RESP:
- Measure range: 0 to 150brpm
- Resolution: 1brpm
- Accuracy: ±2%
- Temperature:
- Measure range: 0 t o50°C
- Accuracy: ±0.1°C
- NIBP:
- Work mode: manual, automatic and continuous
- Unit: mmHg and kPa
- Adult:
- SYS: 40 to 280mmHg
- DIA: 10 to 225mmHg
- MEAN: 20 to 240mmHg
- Pediatric:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- Neonatal:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Resolution: 1mmHg
- Accuracy: ±5mmHg
- 5-lead ECG cable
- Adult finger Spo2 sensor
- NIBP extension tube
- TEMP sensor
- Power cord
- ECG electrodes
- Selectable accessory: (option of one-time use)
- Child finger SPO2
- Child NIBP cuff
- Neonate NIBP cuff
- HS code: 90181930
- Net weight: <5kg
- Gross weight: <8kg
- Dimensions: 320x160x270mm
- Lead mode: I/II/III/AVR/AVL/AVF/V
- Gain: X0.25/X0.5/X1/X2
- Heart rate:
- Adult: 15 to 300bpm
- Neonatal: 15 to 350bpm
- Resolution: 1bpm
- Accuracy: ±1%
- ST measurement range: -2.0, ±2.0mV
- Accuracy: ±10%
- Pacemaker: supported
- Sweep speed: 12.5/25/50mm/second
- Diagnostic: 0.05 to 130Hz
- Monitor: 0.5 to 40Hz
- Surgery: 1 to 20Hz
- Measure range: 0 to 100%
- Resolution: 1%
- Accuracy: 2% (70 to 100%)
- Pulse rate: 20 to 250bpm
- Resolution: 1bpm
- Accuracy: ±3bpm
- Measure range: 0 to 150brpm
- Resolution: 1brpm
- Accuracy: ±2%
- Measure range: 0 t o50°C
- Accuracy: ±0.1°C
- Work mode: manual, automatic and continuous
- Unit: mmHg and kPa
- SYS: 40 to 280mmHg
- DIA: 10 to 225mmHg
- MEAN: 20 to 240mmHg
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Accuracy: ±5mmHg
- Adult: 15 to 300bpm
- Neonatal: 15 to 350bpm
Related Keywords