15-inch Bedside Multiparameter Patient Monitor, Color TFT Screen, 720-hour Trend Records
- Payment Type:
- T/T in Advance, L/C, Western Union, PayPal
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | T/T in Advance, L/C, Western Union, PayPal |
---|
Product Description
Product Description
- 15-inch TFT display
- Resolution: 1,024 x 768 pixels
- Anti-ESU and -defibrillator
- Capture dynamic waveforms
- Can be used for animals
- Trend coexist display
- Spo2 testing to 0.1% weak
- Bed-to-bed view display
- Networking capacity and nurse-calling system
- ECG, SPO2, PR, NIBP, RR and temperature
- With 6 display interfaces
- 720-hour trend data storage and 12-hour waveform review
- Voice alarm
- Supports wired and wireless networking
- Supports software upgrade online
- ST segment can be adjusted
- Supports nurse call system
- ECG:
- Lead mode: 5 leads
- Gain: 1/4, 1/2, 1, 2 and 4mm/mV
- Scanning speed: 12.5, 25 and 50mm/S
- Frequency response:
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
- NIBP:
- Measure and alarm range
- Adult mode:
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
- Pediatric mode:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- Neonatal mode:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Static pressure range: 0 to 300mmHg
- Static pressure accuracy: ±3mmHg or 2%
- Resolution: 1mmHg
- Protection mode and dual over-voltage protection
- SPO2:
- Measure range: 1 to 100%
- Accuracy: ±2% (70 to 100%)
- Resolution: 1%
- Pulse rate measure range: 20 to 300bpm
- Accuracy: ±2bpm
- Resolution: 1bpm
- Temperature:
- Channel: 2
- Measure range: 0 to 50°C
- Accuracy: ±0.1°C
- Resolution: 0.1°C
- Respiration:
- Measure range:
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM
- Accuracy: ±2%
- Resolution: 1bpm
- IBP (optional)
- Accuracy (no sensor): ±2% or 1mmHg
- Measure range:
- Lead mode: 5 leads
- Gain: 1/4, 1/2, 1, 2 and 4mm/mV
- Scanning speed: 12.5, 25 and 50mm/S
- Frequency response:
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
- Measure and alarm range
- Adult mode:
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
- Pediatric mode:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- Neonatal mode:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Static pressure range: 0 to 300mmHg
- Static pressure accuracy: ±3mmHg or 2%
- Resolution: 1mmHg
- Protection mode and dual over-voltage protection
- Measure range: 1 to 100%
- Accuracy: ±2% (70 to 100%)
- Resolution: 1%
- Pulse rate measure range: 20 to 300bpm
- Accuracy: ±2bpm
- Resolution: 1bpm
- Channel: 2
- Measure range: 0 to 50°C
- Accuracy: ±0.1°C
- Resolution: 0.1°C
- Measure range:
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM
- Accuracy: ±2%
- Resolution: 1bpm
- IBP (optional)
- Accuracy (no sensor): ±2% or 1mmHg
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM