Shenzhen Taian Electronics Co. Ltd
Shenzhen Taian Electronics Co. Ltd
Smoke Fire Detector Sensors for Alarm Systems
  • Smoke Fire Detector Sensors for Alarm Systems
Smoke Fire Detector Sensors for Alarm Systems

Smoke Fire Detector Sensors for Alarm Systems

Payment Type:
T/T, Western Union, PayPal, MoneyGram
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T, Western Union, PayPal, MoneyGram
Product Description
Product Description
  • The TA-2988 photoelectric smoke detector is designed to be super-thin with a patch technique and a two-wire and non-polarity system
  • It has a strong anti-interference capability and low power consumption
  • It can be used safely in many different situations
  • The detector's chamber with a y-type labyrinth can dtect effectively the smoke of a smolder fire and smoke given off at the start of a fire
  • The light-sensitive component can detect the light, as the light is scattered in the room after the smoke enters or fills the room
  • When the light strength attains to threshold of the fire alarm, the light (red) of the detector will be bright, and the alarm signal will be transmitted to the exported equipment
  • Every unit is individually tested and calibrated to ensure high reliability and prevent false alarms
  • Specification:
    • Name: smoke/fire detector/sensors (TA-2988)
    • Model: Paradox 643LCD
    • operating voltage: DC 12-24V
    • Monitoring current: ≤50μA
    • Alarm current: ≤20mA
    • Frequency: 3-5s
    • Smoke sensitivity: EN 54-5/7:2000 standard
    • Alarm contact: for 4-wire, n/o or n/c operation
    • Detection range: 100m² rating for smoke sensor, 50m² rating for heat sensor
    • Humidity: 0 to 95% RH, non-condensing
    • Dimensions D*HT): 10x46mm with base
    • Temperature range: -10 to 50°C
    • Remote output: 15mA maximum, diode gate
    • Weight: 130g/set with base
    • Operating environment: temperature, -10-+50°C
    • Relative humidity: ≤95% (40 ± 2°C)
    • Connection method: two-wire and non-polarity system
    • Suitable situations: hotel, apartment, office, machinery room and entertainment places
    • The places having risk of the electric fire
    • None-suitable situations: the places where smoke detained is usual
    • The places where black smoke may be produced in the fire
    • The places there are the dust, fop, steam, oily fog and other decay gas
  • Name: smoke/fire detector/sensors (TA-2988)
  • Model: Paradox 643LCD
  • operating voltage: DC 12-24V
  • Monitoring current: ≤50μA
  • Alarm current: ≤20mA
  • Frequency: 3-5s
  • Smoke sensitivity: EN 54-5/7:2000 standard
  • Alarm contact: for 4-wire, n/o or n/c operation
  • Detection range: 100m² rating for smoke sensor, 50m² rating for heat sensor
  • Humidity: 0 to 95% RH, non-condensing
  • Dimensions D*HT): 10x46mm with base
  • Temperature range: -10 to 50°C
  • Remote output: 15mA maximum, diode gate
  • Weight: 130g/set with base
  • Operating environment: temperature, -10-+50°C
  • Relative humidity: ≤95% (40 ± 2°C)
  • Connection method: two-wire and non-polarity system
  • Suitable situations: hotel, apartment, office, machinery room and entertainment places
  • The places having risk of the electric fire
  • None-suitable situations: the places where smoke detained is usual
  • The places where black smoke may be produced in the fire
  • The places there are the dust, fop, steam, oily fog and other decay gas
  • Send your message to this supplier

    • Mr.  Min

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords