Elec Technologies Group Limited
Elec Technologies Group Limited
650VA UPS
  • 650VA UPS
650VA UPS

650VA UPS

Payment Type:
T/T or L/C
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T or L/C
Product Description
Product Description
  • Auto re-starts when AC recovers
  • Silence setup
  • Emergency power backup protects your valuable data and computerhardware
  • Short-circuit and overload protection
  • Over-charge and over-discharge protection
  • LCD and LED user interface
  • Fax/modem/telephone protection port
  • Users' replaceable batteries
  • Specifications:
    • Wide input voltage range: 75 to 150V AC or 145 to 290V AC
    • Output: 110 or 220V AC ± 10%
    • Frequency range: 50 or 60Hz
    • Transfer time: 10ms or 0ms
    • Battery voltage: 48V DC
    • Maximum battery charging current: >60A
    • LCD display: UPS status, I/P and O/P voltage frequency, load,battery voltage and charge current, temperature and model
    • LED display: normal (green), warning (yellow) and fault(red)
    • Battery: 12V/4.0A, 7.0Ah, 7.5A, 9.0A sealed lead-acidbattery
    • Charge time: 10-16 hours (for offline and line interactivemodels)
    • Operating temperatures: -5 to 40 degrees Celsius
    • Operating humidity range: 10 to 90% RH, non-condensing
    • Powers: 500/600/650/800/850/1,000/1,200/1,500VA foroffline/line interactive and 1, 2,3, 6, 10, 15, 20KVA for onlinemodels
  • Measurements:
  • 305 x 85 x 140mm
  • 324 x 100 x 153mm
  • 350 x 120 x 188mm
  • 340 x 110 x 265mm
  • 441 x 445 x 88mm
  • 482 x 420 x 87mm
  • 600 x 483 x 130mm
  • Wide input voltage range: 75 to 150V AC or 145 to 290V AC
  • Output: 110 or 220V AC ± 10%
  • Frequency range: 50 or 60Hz
  • Transfer time: 10ms or 0ms
  • Battery voltage: 48V DC
  • Maximum battery charging current: >60A
  • LCD display: UPS status, I/P and O/P voltage frequency, load,battery voltage and charge current, temperature and model
  • LED display: normal (green), warning (yellow) and fault(red)
  • Battery: 12V/4.0A, 7.0Ah, 7.5A, 9.0A sealed lead-acidbattery
  • Charge time: 10-16 hours (for offline and line interactivemodels)
  • Operating temperatures: -5 to 40 degrees Celsius
  • Operating humidity range: 10 to 90% RH, non-condensing
  • Powers: 500/600/650/800/850/1,000/1,200/1,500VA foroffline/line interactive and 1, 2,3, 6, 10, 15, 20KVA for onlinemodels
  • Net weight: 5.0-35.0kg
  • Applications:
  • Computers, industries, telecommunications, servers,precisions
  • Instrument, hospitals, government, militaries, CCTV, securitysystems, laboratories, network centers, communication systems, POS,data center, mine fields, railways
  • Send your message to this supplier

    • Ms.  Amy

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords