3 to 25W Power Adapter with Global Mark
- Payment Type:
- Telegraphic Transfer (TT, T/T)
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | Telegraphic Transfer (TT,T/T) |
---|
Product Description
Product Description
- Certifications: UL, cUL, FCC, CCC, PSE, SAA, CE, TUV-GS andBS
- Meet efficiency level: V
- Output:
- Voltages: 3 to 36V DC
- Rated current: 0.1 to 3.2A
- Maximum power: 25W
- Ripple (maximum): 1% type voltage
- Voltage tolerance:
- Input:
- Voltage range: 90 to 264V AC
- Frequency range: 47 to 63Hz
- AC Current: 0.3A/115, 0.21A/230V AC
- Leakage current (maximum): cold start, 30A/115, 50A/230VAC
- Leakage current (maximum): 0.25mA/240V AC
- Protection:
- Over load: more then 105%, rated output power, protection type:hiccup mode, recovers automatically after fault condition isremoved
- Over voltage: 120 to 160%, protection type: clamp by internalcircuit
- Over temperature: 140°C typically, protection type: shutdown o/p voltage, recovers automatically after temperature goesdown
- Environment:
- Working temperature: 0 to 45°C
- Working humidity: 20 to 90% RH (non-condensing)
- Storage temperatures/humidity: -20 to 85°C/10 to 95%RH
- Temperature coefficient: 0.03% (0t o 45°C)
- Vibration: 10 to 500Hz, 2G 10 minutes/1 cycle, period for 60minutes each along X, Y, Z axes
- Safety and EMI:
- Safety standards: GB8898, GB4943, EN/IEC/UL60950,EN/IEC/UL60065
- Withstand voltage: I/P-O/P: 3kV AC
- Isolation resistance: I/P-O/P: 10mM©/500V DC/25°C/70%RH
- EMI conduction and radiation: compliant to FCC part 15 class B,EN55022, EN61204-3 class B
- Harmonic current: compliant to EN61000-3-2, 3
- EMS immunity: compliant to EN61000-4-2, 3, 4, 5000-4-2, 3, 4,5
- Voltages: 3 to 36V DC
- Rated current: 0.1 to 3.2A
- Maximum power: 25W
- Ripple (maximum): 1% type voltage
- Voltage tolerance:
- Voltage range: 90 to 264V AC
- Frequency range: 47 to 63Hz
- AC Current: 0.3A/115, 0.21A/230V AC
- Leakage current (maximum): cold start, 30A/115, 50A/230VAC
- Leakage current (maximum): 0.25mA/240V AC
- Over load: more then 105%, rated output power, protection type:hiccup mode, recovers automatically after fault condition isremoved
- Over voltage: 120 to 160%, protection type: clamp by internalcircuit
- Over temperature: 140°C typically, protection type: shutdown o/p voltage, recovers automatically after temperature goesdown
- Working temperature: 0 to 45°C
- Working humidity: 20 to 90% RH (non-condensing)
- Storage temperatures/humidity: -20 to 85°C/10 to 95%RH
- Temperature coefficient: 0.03% (0t o 45°C)
- Vibration: 10 to 500Hz, 2G 10 minutes/1 cycle, period for 60minutes each along X, Y, Z axes
- Safety standards: GB8898, GB4943, EN/IEC/UL60950,EN/IEC/UL60065
- Withstand voltage: I/P-O/P: 3kV AC
- Isolation resistance: I/P-O/P: 10mM©/500V DC/25°C/70%RH
- EMI conduction and radiation: compliant to FCC part 15 class B,EN55022, EN61204-3 class B
- Harmonic current: compliant to EN61000-3-2, 3
- EMS immunity: compliant to EN61000-4-2, 3, 4, 5000-4-2, 3, 4,5