Succeedin Summer Corp. Ltd
Succeedin Summer Corp. Ltd
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
  • 120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range
120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range

120 to 180W Switching AC/DC Power Supply, 12 to 48V Outputs and 20 to 90% RH Relative Humidity Range

Payment Type:
T/T
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T
Product Description
Product Description
  • Features:
    • Universal AC input
    • High efficiency and high reliability
    • Protections: SCP, OVP, OLP
    • 100% full load burn-in test
    • MBTF: ≥30.000hrs (25℃, full load)
  • Applications:
    • Power tools, network equipment
    • Telecommunications devices
  • Specifications:
    • Inputs:
      • Voltage range: 100-240V AC
      • Frequency range: 50Hz-60Hz
      • AC current (maximum): 1.5A
      • In-rush current (typical): 40A at 115V AC, 60A at 230V AC, cold start
      • Leakage current (primary/secondary): <0.25Ma
    • Outputs:
      • Line regulation: ±2%
      • Load regulation: ±5%
      • Set up time: <3.0S (115V AC input, full load), 1.5S (230V AC input, full load)
      • Hold up time: >10Ms (115V AC input, full load), <20ms (230V AC input, full load)
    • Dimensions (L x W x H): 65 x 36 x 28mm
  • Environments:
    • Operating ambient temperature and humidity range: -0-40℃/5-95% RH
    • Storage temperature and humidity range: -20-85℃, 5%-95% RH
    • Safety and EMC
    • Safety standards: UL60950-1, GB4943-2001, EN60950-1:2006
    • Withstand voltage
    • Input-output: 3.0KV AC, 1min (≦5ma)
    • Isolation resistances: ≧100MΩ at DC 500V
    • EMI conduction and radiation: compliant with EN55022 (CISPR22) ClassB, FCC Part15, GB9254-2008
    • EMS immunity: compliant with EN61000-4-0, 3, 4, 5, 6, 8, 11
  • Lightweight:
    • Smart and convenience
    • Universal input voltage
    • Cooling: natural cooling
    • MTBF: 50,000hrs​​​
    • Certificates: UL, CE, FCC, GS, TUV, SAA, CCC and PSE
  • Universal AC input
  • High efficiency and high reliability
  • Protections: SCP, OVP, OLP
  • 100% full load burn-in test
  • MBTF: ≥30.000hrs (25℃, full load)
  • Power tools, network equipment
  • Telecommunications devices
  • Inputs:
    • Voltage range: 100-240V AC
    • Frequency range: 50Hz-60Hz
    • AC current (maximum): 1.5A
    • In-rush current (typical): 40A at 115V AC, 60A at 230V AC, cold start
    • Leakage current (primary/secondary): <0.25Ma
  • Outputs:
    • Line regulation: ±2%
    • Load regulation: ±5%
    • Set up time: <3.0S (115V AC input, full load), 1.5S (230V AC input, full load)
    • Hold up time: >10Ms (115V AC input, full load), <20ms (230V AC input, full load)
  • Dimensions (L x W x H): 65 x 36 x 28mm
  • Voltage range: 100-240V AC
  • Frequency range: 50Hz-60Hz
  • AC current (maximum): 1.5A
  • In-rush current (typical): 40A at 115V AC, 60A at 230V AC, cold start
  • Leakage current (primary/secondary): <0.25Ma
  • Line regulation: ±2%
  • Load regulation: ±5%
  • Set up time: <3.0S (115V AC input, full load), 1.5S (230V AC input, full load)
  • Hold up time: >10Ms (115V AC input, full load), <20ms (230V AC input, full load)
  • Operating ambient temperature and humidity range: -0-40℃/5-95% RH
  • Storage temperature and humidity range: -20-85℃, 5%-95% RH
  • Safety and EMC
  • Safety standards: UL60950-1, GB4943-2001, EN60950-1:2006
  • Withstand voltage
  • Input-output: 3.0KV AC, 1min (≦5ma)
  • Isolation resistances: ≧100MΩ at DC 500V
  • EMI conduction and radiation: compliant with EN55022 (CISPR22) ClassB, FCC Part15, GB9254-2008
  • EMS immunity: compliant with EN61000-4-0, 3, 4, 5, 6, 8, 11
  • Smart and convenience
  • Universal input voltage
  • Cooling: natural cooling
  • MTBF: 50,000hrs​​​
  • Certificates: UL, CE, FCC, GS, TUV, SAA, CCC and PSE
  • Send your message to this supplier

    • Ms.  Summer Marketing

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords