  • Features:
    • Drug calculation, ST segment detection and pacemaker arrhythmia analysis
    • 5 types of fixed display format includes Oxy CRG diagram, 7 lead ECG waveform simultaneously and large font mode
    • 5 types of user defined display format: display multi-channel real-time waveform and trend diagram same time
    • Audible/visual alarm, apnea alarm available and alarm limits are adjustable
    • WAN communication function to network with central monitoring system, make long distance monitoring, diagnosis, maintenance and software upgrade possible
    • Printing of data, waveform, trend table and trend diagram
    • Complete carting and mounting solution
    • Suitable for adults, pediatrics and neonates
    • Applications in bedside/delivery monitoring: widely used inpatient room, emergency room, PACU, ICU and CCU
  • Specifications:
    • Huge history trend data storage: up to 360 hours
    • ECG:
      • Input: 3/5 wires ECG cable
      • Lead section: I, II, III/ aVR, aVL and aVF/V
      • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
      • Sweep speed: 6.25, 12.5, 25 and 50mm/s
      • Heart rate range: 15 to 380bpm
      • Calibration: ±1mV
    • SpO2:
      • Display types: waveform and data
      • Measurement range: 0 to 100%
      • Accuracy: ± 2%
      • Pulse measurement range: 30 to 250bpm
      • Resolution: ±1bpm
    • NIBP:
      • Philosophy: oscillometric method
      • Measurement types: adult, pediatric and neonate
      • Measurement parameters: systolic, diastolic and mean
      • Measurement methods: manual, automatic and continuous measurement
      • Unit: mmHg/kPa selectable
      • Accuracy: ±2 or 3mmHg
    • Temperature:
      • Number of channels: 2 channels
      • Resolution: 0.1°C
      • Display: T1, T2 and ΔT
    • Respiration:
      • Thoracic impedance, nasal tube double
      • Method delectable
      • Measurement range: 0 to 120bpm
      • Accuracy: ±1bpm
      • Resolution: 1bpm
    • ETCO2:
      • Main/side stream (optional): plug-and-play function
      • Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
      • Accuracy: ±2mmHg
      • Respiration rate: 0 to 150BrPM
      • Accuracy: ±1BrPM
  • Drug calculation, ST segment detection and pacemaker arrhythmia analysis
  • 5 types of fixed display format includes Oxy CRG diagram, 7 lead ECG waveform simultaneously and large font mode
  • 5 types of user defined display format: display multi-channel real-time waveform and trend diagram same time
  • Audible/visual alarm, apnea alarm available and alarm limits are adjustable
  • WAN communication function to network with central monitoring system, make long distance monitoring, diagnosis, maintenance and software upgrade possible
  • Printing of data, waveform, trend table and trend diagram
  • Complete carting and mounting solution
  • Suitable for adults, pediatrics and neonates
  • Applications in bedside/delivery monitoring: widely used inpatient room, emergency room, PACU, ICU and CCU
  • Huge history trend data storage: up to 360 hours
  • ECG:
    • Input: 3/5 wires ECG cable
    • Lead section: I, II, III/ aVR, aVL and aVF/V
    • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
    • Sweep speed: 6.25, 12.5, 25 and 50mm/s
    • Heart rate range: 15 to 380bpm
    • Calibration: ±1mV
  • SpO2:
    • Display types: waveform and data
    • Measurement range: 0 to 100%
    • Accuracy: ± 2%
    • Pulse measurement range: 30 to 250bpm
    • Resolution: ±1bpm
  • NIBP:
    • Philosophy: oscillometric method
    • Measurement types: adult, pediatric and neonate
    • Measurement parameters: systolic, diastolic and mean
    • Measurement methods: manual, automatic and continuous measurement
    • Unit: mmHg/kPa selectable
    • Accuracy: ±2 or 3mmHg
  • Temperature:
    • Number of channels: 2 channels
    • Resolution: 0.1°C
    • Display: T1, T2 and ΔT
  • Respiration:
    • Thoracic impedance, nasal tube double
    • Method delectable
    • Measurement range: 0 to 120bpm
    • Accuracy: ±1bpm
    • Resolution: 1bpm
  • ETCO2:
    • Main/side stream (optional): plug-and-play function
    • Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
    • Accuracy: ±2mmHg
    • Respiration rate: 0 to 150BrPM
    • Accuracy: ±1BrPM
  • Input: 3/5 wires ECG cable
  • Lead section: I, II, III/ aVR, aVL and aVF/V
  • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
  • Sweep speed: 6.25, 12.5, 25 and 50mm/s
  • Heart rate range: 15 to 380bpm
  • Calibration: ±1mV
  • Display types: waveform and data
  • Measurement range: 0 to 100%
  • Accuracy: ± 2%
  • Pulse measurement range: 30 to 250bpm
  • Resolution: ±1bpm
  • Philosophy: oscillometric method
  • Measurement types: adult, pediatric and neonate
  • Measurement parameters: systolic, diastolic and mean
  • Measurement methods: manual, automatic and continuous measurement
  • Unit: mmHg/kPa selectable
  • Accuracy: ±2 or 3mmHg
  • Number of channels: 2 channels
  • Resolution: 0.1°C
  • Display: T1, T2 and ΔT
  • Thoracic impedance, nasal tube double
  • Method delectable
  • Measurement range: 0 to 120bpm
  • Accuracy: ±1bpm
  • Resolution: 1bpm
  • Main/side stream (optional): plug-and-play function
  • Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
  • Accuracy: ±2mmHg
  • Respiration rate: 0 to 150BrPM
  • Accuracy: ±1BrPM