Shenzhen Pilot Guards Safety Technology Co. Ltd
Shenzhen Pilot Guards Safety Technology Co. Ltd
New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
  • New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
  • New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
  • New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity
New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity

New Design CO Detector, PA-001W, OEM/ODM Imported, LCD Display, Ceiling-mounted, High-sensitivity

Payment Type:
T/T or L/C
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T or L/C
Product Description
Product Description
  • Specifications:
    • Power supply: 9V DC
    • Static current: 50µA
    • Response time:
      • At 50ppm, unit must alarm within 60 to 90 minutes
      • At 100ppm, unit must alarm within 10 to 40 minutes
      • At 300ppm, unit must alarm within 3 minutes
    • Operating current: 50uA
    • Alarm volume: 85dB at 10ft (3m)
    • Size (D): 125 x 37mm
    • Range: 0 to 999ppm
    • Operating temperature condition: -5 to 50°C, 20 to 90% RH
    • Compliant with CE standards and the RoHS Directive
    • OEM/ODM services, customized logos and gift boxes are accepted
  • Packaging details:
    • Packaging with white box
    • Carton size: 66 x 27.5 x 28cm
    • Quantity: 100 pieces/carton
    • Net weight: 8kg
    • Gross weight: 9kg
  • Power supply: 9V DC
  • Static current: 50µA
  • Response time:
    • At 50ppm, unit must alarm within 60 to 90 minutes
    • At 100ppm, unit must alarm within 10 to 40 minutes
    • At 300ppm, unit must alarm within 3 minutes
  • Operating current: 50uA
  • Alarm volume: 85dB at 10ft (3m)
  • Size (D): 125 x 37mm
  • Range: 0 to 999ppm
  • Operating temperature condition: -5 to 50°C, 20 to 90% RH
  • Compliant with CE standards and the RoHS Directive
  • OEM/ODM services, customized logos and gift boxes are accepted
  • At 50ppm, unit must alarm within 60 to 90 minutes
  • At 100ppm, unit must alarm within 10 to 40 minutes
  • At 300ppm, unit must alarm within 3 minutes