Shenzhen Orinsong Technology Co. Ltd
Shenzhen Orinsong Technology Co. Ltd
Gas Leak and Heat Detector, AC 220V
  • Gas Leak and Heat Detector, AC 220V
Gas Leak and Heat Detector, AC 220V

Gas Leak and Heat Detector, AC 220V

Payment Type:
Telegraphic Transfer (TT, T/T)
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: Telegraphic Transfer (TT,T/T)
Product Description
Product Description
  • Main features:
    • Wall-mounted, 5 installation methods for various requirements
    • DC 12V/AC 220V, inner switched power supply
    • MCU processing, intelligent analyzing
    • Low power consumption
    • Automatic fault detection, early warning
    • Detachable gas convection window
    • Detachable heat sensor
    • Independent/network/auto shutoff gas valve
    • Adopts SMT, high EMI/RFI immunity
  • Technical specifications:
    • Induced gas: natural gas/LPG
    • Input voltage: DC 12V/AC 220V
    • Operating current: ≤50mA (DC 12V)
    • Alarm current: ≤100mA (DC 12V)
    • Power consumption: <2W
    • Alarm sound level: ≥85dB/m
    • Alarm density: 10% LEL (0.5%) (5000PPM) with CH4
    • Operating temperature: -10°C- +55°C
    • Operating humidity: ≤90% RH
    • Alarm mode: flash and sound alarm/shutoff gas valve/network alarm signal
    • Dimensions: 100*66*33mm
  • Main specifications of heat sensor:
    • Alarm temperature: 57°C/137°F or 8-15°C/min (rate-of-rise)
    • Operating temperature: 0°C to +80°C
    • Operating humidity: ≤90% RH
  • Wall-mounted, 5 installation methods for various requirements
  • DC 12V/AC 220V, inner switched power supply
  • MCU processing, intelligent analyzing
  • Low power consumption
  • Automatic fault detection, early warning
  • Detachable gas convection window
  • Detachable heat sensor
  • Independent/network/auto shutoff gas valve
  • Adopts SMT, high EMI/RFI immunity
  • Induced gas: natural gas/LPG
  • Input voltage: DC 12V/AC 220V
  • Operating current: ≤50mA (DC 12V)
  • Alarm current: ≤100mA (DC 12V)
  • Power consumption: <2W
  • Alarm sound level: ≥85dB/m
  • Alarm density: 10% LEL (0.5%) (5000PPM) with CH4
  • Operating temperature: -10°C- +55°C
  • Operating humidity: ≤90% RH
  • Alarm mode: flash and sound alarm/shutoff gas valve/network alarm signal
  • Dimensions: 100*66*33mm
  • Alarm temperature: 57°C/137°F or 8-15°C/min (rate-of-rise)
  • Operating temperature: 0°C to +80°C
  • Operating humidity: ≤90% RH