Idealink Network Technology Co.,Ltd
Idealink Network Technology Co.,Ltd
Solid Bare Copper Conductor Cat6 LAN Cable, Packed with 1,000ft or 305m/Box, 0.24mm Thickness
  • Solid Bare Copper Conductor Cat6 LAN Cable, Packed with 1,000ft or 305m/Box, 0.24mm Thickness
Solid Bare Copper Conductor Cat6 LAN Cable, Packed with 1,000ft or 305m/Box, 0.24mm Thickness

Solid Bare Copper Conductor Cat6 LAN Cable, Packed with 1,000ft or 305m/Box, 0.24mm Thickness

Payment Type:
Telegraphic Transfer (TT, T/T)
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: Telegraphic Transfer (TT,T/T)
Product Description
Product Description
  • Specifications:
    • Conductor: solid bare copper
    • AWG: 23
    • Conductor diameter: 0.57mm
    • Insulation: PE
    • Average thickness (±0.03mm): 0.24mm
    • Minimum point thickness: 0.24mm
    • Insulation diameter (±0.03mm): 1.00mm
    • Twisting lay length: 30mm, underneath
    • Cabling lay length: 200mm, underneath
    • Jacket: PVC/LSZH
    • Average thickness: 0.5mm
    • Minimum point thickness: 0.4mm
    • Outer diameter (±1.00mm): 6.6mm
    • Rip cord: supported
    • Weight nom: 60kg/km
    • Core colors:
      • Pair 1: blue-white/blue
      • Pair 2: orange-white/orange
      • Pair 3: green-white/orange
      • Pair 4: brown-white/brown
  • Electrical performance (at 250MHz):
    • 1.0 to 100.0MHz, impedance: 100 ±15©
    • 100.0 to 250.0MHz, impedance: 100 ±22©
    • Impedance delay screw: <45ns/100m
    • Pair to ground capacitance unbalance: 330pF/100m (maximum)
    • Conductor DC resistance 20%: <73.2©/km
    • Resistance unbalance: 5%
    • Test object: jacket
    • Test material: PVC
    • Before tensile strength: e13.8MPa
    • Aging elongation: e100%
    • Aging condition: 100 x 240 (C x hours)
    • After tensile strength: e85%MPa of unaged
    • Aging elongation: e50% of unaged
    • Cold bend (-20 ±2°C x 4 hours): no crock
  • LAN cable standard compliance:
    • All proposed category 6 requirements: as per your ANSI/TIA/EIA, IEC and CENELEC Ethernet standards
    • ANSI/TIA/EIA 568-B.2-1 Cat6
    • IEC 11801 class E 2nd edition
    • Cenelec EN 61156-6
    • Cenelec EN 50173-1
    • Cenelec EN 50288-5-1 and Cenelec EN 50288-5-2
    • Flame-retardant is verified according to IEC 60332-1-2
  • OEM service:
    • Conductor: solid bare copper/CCS/CCA
    • AWG: 23/24
    • Insulation: foam PE/solid PE
    • Jacket: PVC/LSZH
  • Applications:
    • Pots.T1 and T1 fractional, ISDN basic and primary rate
    • 4/16Mbps token ring (IEEE802.5) and 10Base-T (IEEE802.5)
    • 100Mbps TP-PMD.52/155Mbps (ATM forum)
    • 100Base-T4 (Ethernet)
    • 100 VG any LAN (IEEE802.12)
    • 100Base-T (fast Ethernet)
    • 1Gbps Ethernet (IEEE802.3)
  • Packing: wooden roller
  • Conductor: solid bare copper
  • AWG: 23
  • Conductor diameter: 0.57mm
  • Insulation: PE
  • Average thickness (±0.03mm): 0.24mm
  • Minimum point thickness: 0.24mm
  • Insulation diameter (±0.03mm): 1.00mm
  • Twisting lay length: 30mm, underneath
  • Cabling lay length: 200mm, underneath
  • Jacket: PVC/LSZH
  • Average thickness: 0.5mm
  • Minimum point thickness: 0.4mm
  • Outer diameter (±1.00mm): 6.6mm
  • Rip cord: supported
  • Weight nom: 60kg/km
  • Core colors:
    • Pair 1: blue-white/blue
    • Pair 2: orange-white/orange
    • Pair 3: green-white/orange
    • Pair 4: brown-white/brown
  • Pair 1: blue-white/blue
  • Pair 2: orange-white/orange
  • Pair 3: green-white/orange
  • Pair 4: brown-white/brown
  • 1.0 to 100.0MHz, impedance: 100 ±15©
  • 100.0 to 250.0MHz, impedance: 100 ±22©
  • Impedance delay screw: <45ns/100m
  • Pair to ground capacitance unbalance: 330pF/100m (maximum)
  • Conductor DC resistance 20%: <73.2©/km
  • Resistance unbalance: 5%
  • Test object: jacket
  • Test material: PVC
  • Before tensile strength: e13.8MPa
  • Aging elongation: e100%
  • Aging condition: 100 x 240 (C x hours)
  • After tensile strength: e85%MPa of unaged
  • Aging elongation: e50% of unaged
  • Cold bend (-20 ±2°C x 4 hours): no crock
  • All proposed category 6 requirements: as per your ANSI/TIA/EIA, IEC and CENELEC Ethernet standards
  • ANSI/TIA/EIA 568-B.2-1 Cat6
  • IEC 11801 class E 2nd edition
  • Cenelec EN 61156-6
  • Cenelec EN 50173-1
  • Cenelec EN 50288-5-1 and Cenelec EN 50288-5-2
  • Flame-retardant is verified according to IEC 60332-1-2
  • Conductor: solid bare copper/CCS/CCA
  • AWG: 23/24
  • Insulation: foam PE/solid PE
  • Jacket: PVC/LSZH
  • Pots.T1 and T1 fractional, ISDN basic and primary rate
  • 4/16Mbps token ring (IEEE802.5) and 10Base-T (IEEE802.5)
  • 100Mbps TP-PMD.52/155Mbps (ATM forum)
  • 100Base-T4 (Ethernet)
  • 100 VG any LAN (IEEE802.12)
  • 100Base-T (fast Ethernet)
  • 1Gbps Ethernet (IEEE802.3)
  • Send your message to this supplier