Switching Power Supply with 100 Watts for CCTV Security Camera Device
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | T/T |
---|
Product Description
Product Description
- High price-effective, reliability with industry standards
- Built-in over-voltage, over-current and short-circuitprotection
- Certificates: CE, CCC
- Input: 110/220V AC ±15%
- Frequency: 50/60Hz, <1.5A
- Line regulation range: ±0.5 (maximum)
- Start up current: 40A/230V AC
- Output:
- Line regulation range: ±0.5% (maximum)
- Ripple and noise: <1%mVp-p of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1 second (AC input 240V and Io = 100%)
- Hold-up time: e20 minutes (AC input 240V and Io = 100%)
- Temperature quantity: ±0.02%/°C
- Protection:
- Overloading protection: 115 to 150% of rated power, when ithappened, the power shuts down automatically, when trouble removedthe power recovers itself
- Over voltage protection: 130 to 150% of rated voltage
- Short circuit protection
- Insulation intensity:
- Input-output: 1,500V/5mA, 60 seconds
- Input-ground: 1,500V/5mA, 60 seconds
- Output-ground: 1,500V/5mA, 60 seconds
- Insulation resistance:
- Input-output: e50m©, 500V DC
- Input-ground: e50m©, 500V DC
- Output-ground: e50m©, 500V DC
- Environmental requirements:
- Operating temperature: 0 to 40°C
- Operating humidity: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity: 10 to 95% RH (no freezing dew)
- Elevation: <3,000m
- Dimensions (L x W x H): 199 x 98 x 39mm
- Weight: 650g
- EMC: EN55022B, GB9254
- Line regulation range: ±0.5% (maximum)
- Ripple and noise: <1%mVp-p of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1 second (AC input 240V and Io = 100%)
- Hold-up time: e20 minutes (AC input 240V and Io = 100%)
- Temperature quantity: ±0.02%/°C
- Overloading protection: 115 to 150% of rated power, when ithappened, the power shuts down automatically, when trouble removedthe power recovers itself
- Over voltage protection: 130 to 150% of rated voltage
- Short circuit protection
- Input-output: 1,500V/5mA, 60 seconds
- Input-ground: 1,500V/5mA, 60 seconds
- Output-ground: 1,500V/5mA, 60 seconds
- Input-output: e50m©, 500V DC
- Input-ground: e50m©, 500V DC
- Output-ground: e50m©, 500V DC
- Operating temperature: 0 to 40°C
- Operating humidity: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity: 10 to 95% RH (no freezing dew)