
48W Switching Power Supply with All International Safety Certifications
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | T/T |
---|
Product Description
Product Description
- High price-effective, reliability with industry standards
- Built-in over-voltage, over-current and short-circuitprotections
- With CE and CCC marks
- Input:
- Voltage: 90 to 264V AC ±15%
- Frequency: 50/60Hz at 0.6A
- Line regulation range: ±0.5 (maximum)
- Start-up current: 40A/230V AC
- Output:
- Line regulation range: ±0.5% (maximum)
- Ripple and noise (mVp-p): <1% of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1 second (AC input 240V and Io = 100%)
- Hold-up time: e20 minutes (AC input 240V and Io = 100%)
- Temperature quotient: ±0.02%/°C
- Protections:
- Overloading: 115 to 150% of rated power, when it happened, thepower shutdown automatically, when trouble removed the powerrecovers itself
- Over-voltage: 130 to 150% of rated voltage
- Short-circuit
- Insulation intensity:
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 1,500V/5mA, 60 seconds
- Insulation resistance:
- Input/output: e50m©, 500V DC
- Input/ground: e50m©, 500V DC
- Output/ground: e50m©, 500V DC
- Environment requirements:
- Operating temperature: 0 to 40°C
- Operating humidity: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity: 10 to 95% RH (no freezing dew)
- Elevation: <3,000m
- Dimensions (L x W x H): 110 x 78 x 36mm
- Weight: 280g
- EMC: EN55022B and GB9254
- Voltage: 90 to 264V AC ±15%
- Frequency: 50/60Hz at 0.6A
- Line regulation range: ±0.5 (maximum)
- Start-up current: 40A/230V AC
- Line regulation range: ±0.5% (maximum)
- Ripple and noise (mVp-p): <1% of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1 second (AC input 240V and Io = 100%)
- Hold-up time: e20 minutes (AC input 240V and Io = 100%)
- Temperature quotient: ±0.02%/°C
- Overloading: 115 to 150% of rated power, when it happened, thepower shutdown automatically, when trouble removed the powerrecovers itself
- Over-voltage: 130 to 150% of rated voltage
- Short-circuit
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 1,500V/5mA, 60 seconds
- Input/output: e50m©, 500V DC
- Input/ground: e50m©, 500V DC
- Output/ground: e50m©, 500V DC
- Operating temperature: 0 to 40°C
- Operating humidity: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity: 10 to 95% RH (no freezing dew)
Related Keywords
Related Keywords
You May Also Like
You May Also Like