Industry SMPS with 60W Power, High-stability, 120mV Ripple and 176 to 264V AC Voltage
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | T/T |
---|
Product Description
Product Description
- Input:
- Voltage: 176 to 264V AC
- Frequency: 50/60Hz at <1A
- Line regulation range: ±0.5 (maximum)
- Output:
- Line regulation range: ±0.5% maximum
- Ripple and noise (mVp-p): <1% of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1s (AC input 240V and Io=100%)
- Hold-up time: e20ms (AC input 240V and Io=100%)
- Protections:
- Overloading protection: 115 to 150% of rated power, when ithappened, the power shuts down automatically, when trouble removedthe power recovers itself
- Over-voltage protection: 130 to 150% of rated voltage
- Over-current protection
- Insulation intensity:
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 500V/5mA, 60 seconds
- Insulation intensity:
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 1,500V/5mA, 60 seconds
- Environment requirement:
- Operating temperature: 0 to 40°C
- Operating humidity range: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity range: 10 to 95% RH (no freezing dew)
- Elevation: <3,000m
- Dimensions (L x W x H): 143 x 59 x 39mm
- Weight: 300g
- EMC: EN55022 and GB3954
- Voltage: 176 to 264V AC
- Frequency: 50/60Hz at <1A
- Line regulation range: ±0.5 (maximum)
- Line regulation range: ±0.5% maximum
- Ripple and noise (mVp-p): <1% of output voltage
- Adjustable range of output voltage: ±3%
- Start-up time: d1s (AC input 240V and Io=100%)
- Hold-up time: e20ms (AC input 240V and Io=100%)
- Overloading protection: 115 to 150% of rated power, when ithappened, the power shuts down automatically, when trouble removedthe power recovers itself
- Over-voltage protection: 130 to 150% of rated voltage
- Over-current protection
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 500V/5mA, 60 seconds
- Input/output: 1,500V/5mA, 60 seconds
- Input/ground: 1,500V/5mA, 60 seconds
- Output/ground: 1,500V/5mA, 60 seconds
- Operating temperature: 0 to 40°C
- Operating humidity range: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity range: 10 to 95% RH (no freezing dew)