UK Plug 12V DC 1.5A Power Adapter with CE Approval, Security Alarm System Power Supply
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | T/T |
---|
Product Description
Product Description
- For security alarm system
- Input: 100 to 240VAC
- Output: 12V DC 1.5A
- AC input between the two poles
- SCP/OCP/OVP/OTP
- Class II standard, high insulation
- Power consumption (without load) is less than 0.5W
- One year warranty
- RoHS directive-compliant
- Environment:
- Working temperature: -10 to +40 degrees Celsius
- Storage temperature: -25 to +75 degrees Celsius
- Related humidity: 20 to 90% RH
- Cooling method: cooling by air convection
- Elevation: ≤3,000m
- Input:
- Rated input voltage: 100 to 240V AC
- Input voltage range: 90 to 264V AC
- Input current: less than 0.8A
- Power consumption: 0.5W, 100 to 240V AC input
- Power factor: PF
- Input frequency range: 50 to 60 HZ
- Efficiency: greater than75%
- Output:
- Voltage without load: 12V +5% V DC
- Load range: 0 to 1.5A
- Ripple: less than 30mV
- Peak: less than 80mV
- Start time: less than 3S, 220V AC IO = 100%
- Hold up time: >20mS, 220V AC IO = 100%
- OCP: rated current 150 to 200%
- SCP: short circuit power is 0.5W min recoverable
- OVP: 13V (unrecoverable)
- Working temperature: -10 to +40 degrees Celsius
- Storage temperature: -25 to +75 degrees Celsius
- Related humidity: 20 to 90% RH
- Cooling method: cooling by air convection
- Elevation: ≤3,000m
- Rated input voltage: 100 to 240V AC
- Input voltage range: 90 to 264V AC
- Input current: less than 0.8A
- Power consumption: 0.5W, 100 to 240V AC input
- Power factor: PF
- Input frequency range: 50 to 60 HZ
- Efficiency: greater than75%
- Voltage without load: 12V +5% V DC
- Load range: 0 to 1.5A
- Ripple: less than 30mV
- Peak: less than 80mV
- Start time: less than 3S, 220V AC IO = 100%
- Hold up time: >20mS, 220V AC IO = 100%