Maternal & Fetal Monitor,nine para
Optional:twins fuction
Feature:
Probe: Solid and durable, anti-shock and anti-falling down.
Multi-fetus: Single fetus,twin fetus,tri-fetus are optional.
Multi-parameter: Real-time Matemal SPO2 and NIBP monitor.
Patent: Special fetus awaking function within FHR probe.
Three to one design: Special three to one design among FHR probe, TOCO probe, fetal movement marker, avoid twisting
Tone: Quality speaker take more clear and loud sound.
System: Operate and control mutually with center monitor.

Specification:
Ultrasound: Multi wafer, wide wave-beam.
Ultrasound frequency: 0.8-2.2MHz+-5%
Ultrasound intensity: <5mW/cm2
TOCO transducer: external transducer
FHR range: 30-210bpm
TOCO range: 0-100 (relative unit)
Power: AC 220V 50Hz
Paper: 112mm thermal
Weight: 3.65KG
Size: 340mm X 310mm X 125mm
Working condition: Temperature 10-45
                   Humidity 10-80%

                                                                                                  Technical parameters
 
Ultrasound frequency 1MHz± 5%
Power supply AC100~240V 50/60Hz
Working temperature (centidegree) 5~40
Working humidity < 85%
Working atmospheric pressure (KPa) 86~106
Storage temperature (centidegree) -10~+55
Storage relative humidity < 93%
Storage atmospheric pressure 86~106
Machine0.2% Dimension (mm)
 
Net weight          
 
FM Button hand count automatic cumulative number of movement
ECG Range 30~300bpm
Accuracy ± 1bpm
Choice I, II. III, AVR, AVL, AVF, V
Scan speed 12.5/25/50mm/s
Gain choice *0.25, *0.5, *1, *2
Application Diagnosis, monitor, surgery
RESP Range 1~99rpm
Resolution 1rpm
Accuracy ± 2rpm
TEMP            Range 26~45 celsius degree
Resolution 0.1 celsius degree
Accuracy ± 0.2%
FHR Ultrasound intensity < 5mW/cm 2
Measure range (bpm) 50~210
Alarm range (bpm) H: 160/170/180/190
L: 90/100/110/120
Maximum audio output power 1.5W
TOCO Measure range 0~100 unit
Resolution 1
Non-linear error ≤ ± 5%
Maternal HR Measure scope (bpm) 30~240
Measure accuracy (bpm) ± 2
Maternal SPO2 Measure scope 70%~99%
Resolution 1%
Measure accuracy ± 2bpm
NIBP Systolic pressure 50~240 mmHg
Diastolic pressure 15~180 mmHg
Mean pressure 25~200 mmHg
NIBP accuracy ± 8mmHg
PR PR range 40~240bpm
Mode Automanual
Resolution 1 mmHg
PR accuracy ± 2bpm
 