Shenzhen Jumper Medical Equipment Co., Ltd.
Shenzhen Jumper Medical Equipment Co., Ltd.
Fetal& Maternal Monitor Jpd-600p (12.1inch) CE Marked
  • Fetal& Maternal Monitor Jpd-600p (12.1inch) CE Marked
Fetal& Maternal Monitor Jpd-600p (12.1inch) CE Marked

Fetal& Maternal Monitor Jpd-600p (12.1inch) CE Marked

Payment Type:
L/C, T/T, Paypal, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen China
Payment Type: L/C, T/T, Paypal, Western Union
Product Description
Product Description

Product Description
Fetal & Maternal Monitor JPD-600P 12.1 inch CE marked 6 parameters, Twins function.

Function:

Prevent the fetus from lacking of O2, acidosis and other unsafe factors through monitoring the TOCO, FHR and FM.
Standard configuration: FHR, TOCO, FM, SpO2, NIBP, PR, Twins Function
Optional configuration: ECG, TEMP, RESP, ETCO2, IBP, Anesthetic depth

Feature:

1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12/24 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable Information and RJ45 connector, can be connected in the hospital monitor center
11. Can work during charging, high anti-interference ability
12. Light weight, space-saving, easy operation
13. FM automatic test

Specification:

Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler, high sensitively
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: Special DSP system and modern recognization.
Measurement range: 50~210 bpm
Alarm Range:
High limit: 160, 170, 180, 190 bpm
Low limit: 90, 100, 110, 120 bpm
Maximum audio output power: 1.5 Watt
Toco:
Measurement range: 0~100 units
Maternal SpO2 measure:
Measure scope: 70%~99%.
Measure accuracy: ± 3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ± 2 bpm
NIBP measure:
A) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)
B) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
C) NIBP-MEAN(2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ± 1.1kPa(± 8mmHg)or ± 5% of the results, take the bigger one.
Maximum Mean error: ± 5mmHg
Maximum Standard deviation: 8mmHg
Pulse Rate Accuracy: Maximum Mean error: ± 2bpm
Measure accuracy: ± 2 bpm or ± 5% of the results, take the bigger one.
Measure mode: Manual
Display:
The LCD displays FHR, TOCO, FM, maternal parameters, time, date, volume and so on, It can store and play back the data.
Power: A. C. 100-240v, 50/60Hz, d. C. 15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307 (length) × 296 (width) × 101 (height) (mm)
Net weight: Three-parameter type: 2.75kg; Nine-parameter type: 3kg. (Both does not contain accessories such as probe)


Technical parameters
 
Ultrasound frequency 1MHz± 5%
Power supply AC100~240V 50/60Hz
Working temperature (centidegree) 5~40
Working humidity < 85%
Working atmospheric pressure (KPa) 86~106
Storage temperature (centidegree) -10~+55
Storage relative humidity < 93%
Storage atmospheric pressure 86~106
Machine0.2% Dimension (mm)
Net weight            
FM Button hand count automatic cumulative number of movement
ECG Range 30~300bpm
Accuracy ± 1bpm
Choice I, II. III, AVR, AVL, AVF, V
Scan speed 12.5/25/50mm/s
Gain choice *0.25, *0.5, *1, *2
Application Diagnosis, monitor, surgery
RESP Range 1~99rpm
Resolution 1rpm
Accuracy ± 2rpm
TEMP              Range 26~45 centidegree
Resolution 0.1centidegree
Accuracy ± 0.2%
FHR Ultrasound intensity < 5mW/cm 2
Measure range (bpm) 50~210
Alarm range (bpm) H: 160/170/180/190
L: 90/100/110/120
Maximum audio output power 1.5W
TOCO Measure range 0~100 unit
Resolution 1
Non-linear error ≤ ± 5%
Maternal HR Measure scope (bpm) 30~240
Measure accuracy (bpm) ± 2
Maternal SPO2 Measure scope 70%~99%
Resolution 1%
Measure accuracy ± 2bpm
NIBP Systolic pressure 50~240 mmHg
Diastolic pressure 15~180 mmHg
Mean pressure 25~200 mmHg
NIBP accuracy ± 8mmHg
PR PR range 40~240bpm
Mode Automanual
Resolution 1 mmHg
PR accuracy ± 2bpm

Send your message to this supplier

  • Ms. Wendy

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords