Fetal& Maternal Monitor Jpd-600p (12.1inch) CE Marked
- Payment Type:
- L/C, T/T, Paypal, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen China |
---|---|
Payment Type: | L/C, T/T, Paypal, Western Union |
Product Description
Product Description
Product Description
Fetal & Maternal Monitor JPD-600P 12.1 inch CE marked 6 parameters, Twins function.
Function:
Prevent the fetus from lacking of O2, acidosis and other unsafe factors through monitoring the TOCO, FHR and FM.
Standard configuration: FHR, TOCO, FM, SpO2, NIBP, PR, Twins Function
Optional configuration: ECG, TEMP, RESP, ETCO2, IBP, Anesthetic depth
Feature:
1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12/24 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable Information and RJ45 connector, can be connected in the hospital monitor center
11. Can work during charging, high anti-interference ability
12. Light weight, space-saving, easy operation
13. FM automatic test
Specification:
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler, high sensitively
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: Special DSP system and modern recognization.
Measurement range: 50~210 bpm
Alarm Range:
High limit: 160, 170, 180, 190 bpm
Low limit: 90, 100, 110, 120 bpm
Maximum audio output power: 1.5 Watt
Toco:
Measurement range: 0~100 units
Maternal SpO2 measure:
Measure scope: 70%~99%.
Measure accuracy: ± 3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ± 2 bpm
NIBP measure:
A) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)
B) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
C) NIBP-MEAN(2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ± 1.1kPa(± 8mmHg)or ± 5% of the results, take the bigger one.
Maximum Mean error: ± 5mmHg
Maximum Standard deviation: 8mmHg
Pulse Rate Accuracy: Maximum Mean error: ± 2bpm
Measure accuracy: ± 2 bpm or ± 5% of the results, take the bigger one.
Measure mode: Manual
Display:
The LCD displays FHR, TOCO, FM, maternal parameters, time, date, volume and so on, It can store and play back the data.
Power: A. C. 100-240v, 50/60Hz, d. C. 15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307 (length) × 296 (width) × 101 (height) (mm)
Net weight: Three-parameter type: 2.75kg; Nine-parameter type: 3kg. (Both does not contain accessories such as probe)
Technical parameters | |||
Ultrasound frequency | 1MHz± 5% | ||
Power supply | AC100~240V 50/60Hz | ||
Working temperature (centidegree) | 5~40 | ||
Working humidity | < 85% | ||
Working atmospheric pressure (KPa) | 86~106 | ||
Storage temperature (centidegree) | -10~+55 | ||
Storage relative humidity | < 93% | ||
Storage atmospheric pressure | 86~106 | ||
Machine0.2% Dimension (mm) | |||
Net weight | |||
FM | Button hand count automatic cumulative number of movement | ||
ECG | Range | 30~300bpm | |
Accuracy | ± 1bpm | ||
Choice | I, II. III, AVR, AVL, AVF, V | ||
Scan speed | 12.5/25/50mm/s | ||
Gain choice | *0.25, *0.5, *1, *2 | ||
Application | Diagnosis, monitor, surgery | ||
RESP | Range | 1~99rpm | |
Resolution | 1rpm | ||
Accuracy | ± 2rpm | ||
TEMP | Range | 26~45 centidegree | |
Resolution | 0.1centidegree | ||
Accuracy | ± 0.2% | ||
FHR | Ultrasound intensity | < 5mW/cm 2 | |
Measure range (bpm) | 50~210 | ||
Alarm range (bpm) | H: 160/170/180/190 | ||
L: 90/100/110/120 | |||
Maximum audio output power | 1.5W | ||
TOCO | Measure range | 0~100 unit | |
Resolution | 1 | ||
Non-linear error | ≤ ± 5% | ||
Maternal HR | Measure scope (bpm) | 30~240 | |
Measure accuracy (bpm) | ± 2 | ||
Maternal SPO2 | Measure scope | 70%~99% | |
Resolution | 1% | ||
Measure accuracy | ± 2bpm | ||
NIBP | Systolic pressure | 50~240 mmHg | |
Diastolic pressure | 15~180 mmHg | ||
Mean pressure | 25~200 mmHg | ||
NIBP accuracy | ± 8mmHg | ||
PR | PR range | 40~240bpm | |
Mode | Automanual | ||
Resolution | 1 mmHg | ||
PR accuracy | ± 2bpm |
Related Keywords
Related Keywords