Shenzhen Jumper Medical Equipment Co., Ltd.
Shenzhen Jumper Medical Equipment Co., Ltd.
Fetal Monitor Fhr, Toco, FM, with Printer
  • Fetal Monitor Fhr, Toco, FM, with Printer
Fetal Monitor Fhr, Toco, FM, with Printer

Fetal Monitor Fhr, Toco, FM, with Printer

Payment Type:
L/C, T/T
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen China
Payment Type: L/C, T/T
Product Description
Product Description
Specifications: 1.7'' TFT color screen, 90 degree flip; 2. Twins FHR, maternal SpO2, NIBP and PR are optional; 3. Compact abd portable design. CE marked 7 inches color screen fetal monitor1. Default configuaration1.1 Main unit: The main unit has the LCD module, recorder and electronic circuitry-microprocessor, signal Processing, audio system, display systems and power supply. Signals from the transducers are processed and displayed On the large LCD display. And the menu can be adjust by encoder. Tthe key on control panel can be set up the system parameter, freeze display, adjust volume, printer control, alarm control and so on. 1.2 adapter and power wire. 1.3 3 in 1 transducer (U/S, TOCO and Remote Even market), U/S2 transducer(option), maternal SpO2 sensor(option), blood pressure cuff(option). The 3-in-1 transducer are held inplace on the abdomen by elastic straps. The pregnant woman hold the marker, push the button when she feels fetal moving or uterine activity. 2. SpecificationTransducer: Multi-crystals, pulsed doppler, high sensitivelyStrength: <5mW/cm2Working frequency: 1.0MHzSignal processing: Special DSP system and modern recognization. Measurement range: 50~210 bpmAlarm Range: High limit: 160, 170, 180, 190 bpmLow limit: 90, 100, 110, 120 bpmMaximum audio output power: 1.5 WattToco: Measurement range: 0~100 unitsMaternal SpO2 measure: Measure scope: 70%~99%. Measure accuracy: ± 3%Pregnant HR Measure: Measure scope: 30bpm~240bpm. Measure accuracy: ± 2 bpmNIBP measure: A) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)B) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)C) NIBP-MEAN(2.0~24.0ka(15~180mmHg)NIBP Accuracy: ± 1.1kPa(± 8mmHg)or ± 5% of the results, take the bigger one. Maximum Mean error: ± 5mmHgMaximum Standard deviation 8mmHgPulse Rate Accuracy: Maximum Mean error: ± 2bpmMeasure accuracy: ± 2 bpm or ± 5% of the results, take the bigger one. Measure mode: ManualDisplay: The LCD displays FHR, TOCO, FM, maternal parameters, time, date, volume and so on, It can store and playBack the data. Power: A. C. 100-240V, 50/60Hz or 8.4 Li-LONPower Consumption: < 20WDimension: 295W× 240D× 73H(mm)Net weight: 1.75kgWorking Environment: Temperature: 5~40° C. Relative humidity: 10~80%Transducer Acoustic Output: Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-average intensity does not exceed 100mW/cm2GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, bacteriostatic (not sterile). 1.7'' TFT color screen, 90 degree flip; 2. Twins FHR, maternal SpO2, NIBP and PR are optional; 3. Compact abd portable desige

Send your message to this supplier

  • Ms. Wendy

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords