Multi-Parameters fetal monitor JPD-600P(7 inch) CE marked
Bedside care, normal hospital monitor

Hospital Fetal Monitor-Multi Usage Jpd-600p (7 inch) CE Marked


Standard configuration: FHR, TOCO, FM SpO2, NIBP, PR

Feture:

1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable
11. Information and RJ45 connector, can be connected in the hospital monitor center
12. Can work during charging, high anti-interference ability

GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, bacteriostatic (not sterile).

Technical Parameter:

Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively  
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing:  special DSP system and modern recognization.
Measurement range:  60 bpm ~210 bpm
Alarm Range:
High limit: 160 bpm,170 bpm,180 bpm,190 bpm
Low limit: 90 bpm,100 bpm,110 bpm,120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0 units ~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a)   NIBP-SYS  6.7Kpa~32.0Kpa (50mmHg~240mmHg)
b)  NIBP-DIA  3.4Kpa~26.6Kpa (25mmHg~200mmHg)
c)NIBP-MEAN 2.0Kpa~24.0kpa (15mmHg~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm  
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual 
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play back the data.
Power: a.c.100v - 240v, 50/60Hz ,d.c.15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307mm (length) ×296mm (width) ×101mm (height) 
Net weight: Three-parameter type: 2.75kg; nine-parameter type: 3kg. (Both does not contain accessories such as probe)
Environment 
Working environment: Temperature: +5ºC ~ +40ºC
Humidity: < 85%
Atmospheric pressure: 86kPa ~ 106kPa
Transport and storage temperature: Temperature: -10ºC ~ +55ºC
Humidity: < 93%
Atmospheric pressure: 86kPa ~ 106kPa
Transducer Acoustic Output: 
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2


Technical parameters
 
Ultrasound frequency 1MHz± 5%
Power supply AC100~240V 50/60Hz
Working temperature (centidegree) 5~40
Working humidity < 85%
Working atmospheric pressure (KPa) 86~106
Storage temperature (centidegree) -10~+55
Storage relative humidity < 93%
Storage atmospheric pressure 86~106
Machine0.2% Dimension (mm)
Net weight                
FM Button hand count automatic cumulative number of movement
ECG Range 30~300bpm
Accuracy ± 1bpm
Choice I, II. III, AVR, AVL, AVF, V
Scan speed 12.5/25/50mm/s
Gain choice *0.25, *0.5, *1, *2
Application Diagnosis, monitor, surgery
RESP Range 1~99rpm
Resolution 1rpm
Accuracy ± 2rpm
TEMP                  Range 26~45 centidegree
Resolution 0.1centidegree
Accuracy ± 0.2%
FHR Ultrasound intensity < 5mW/cm 2
Measure range (bpm) 50~210
Alarm range (bpm) H: 160/170/180/190
L: 90/100/110/120
Maximum audio output power 1.5W
TOCO Measure range 0~100 unit
Resolution 1
Non-linear error ≤ ± 5%
Maternal HR Measure scope (bpm) 30~240
Measure accuracy (bpm) ± 2
Maternal SPO2 Measure scope 70%~99%
Resolution 1%
Measure accuracy ± 2bpm
NIBP Systolic pressure 50~240 mmHg
Diastolic pressure 15~180 mmHg
Mean pressure 25~200 mmHg
NIBP accuracy ± 8mmHg
PR PR range 40~240bpm
Mode Automanual
Resolution 1 mmHg
PR accuracy ± 2bpm


Hospital Fetal Monitor-Multi Usage Jpd-600p (7 inch) CE Marked
Faults Probable causes Approaches
No displaying after start Power cord is not plugged well
Power failure or poor power plug or socket
Inspect the power and power cord 
When start the instrument, the LCD interface is normal but can't move the cursor.  Poor or broken connect between fetal monitoring module and motherboard Connect again or replace the module 
Fetal heart rate is abnormal Poor connect of probe and connector
The probe position is wrong and the probe does not find fetal heart. 
No coupling agent or the coupling agent is too little.
Fetus/Pregnant women's movement
The probe is broken.
Connect again
Readjust the probe position
Add coupling agent
When there is signal again, readjust the probe position.
Replace the probe.
 
Uterine contraction is abnormal Poor connect of probe and instrument
The probe position is wrong.
The pressure has not been reset.
Pregnant women have no uterine contraction
Connect again
Readjust the probe position
Reset the pressure
Wait for uterine contraction
 
When press the pressure probe, there is no change or little change of the uterine contraction numerical value. Drift of pressure probe internal circuit or the pressure probe is broken Adjust the potentiometer in the side holes of pressure probe by straight screwdriver fixing watches to make the probe can read normal numerical value when pressing.
Replace the pressure probe.
Press fetal movement pen, there is no display and printing icon. Poor contact of scaler button switch Inspected and determined by universal meter 
The speaker is mute. The volume is too low. Turn up the volume.
The paper is running but no printing curve. Fetal heart curve is printed in uterine contraction area and uterine contraction curve is printed in fetal heart area. The placement of thermal printing paper is adverse.
The left and right sides of thermal surface are adverse.
 
Inspect whether thermal surface
is upward and place paper again
Take out the thermal paper and place again.
 
The printing is not clear or there can't print in partial area. The printing denseness is set too light
Poor printing paper has been used or the printing paper is subject to deterioration
The printing thermal head is dirty.
Adjust printing denseness
Replace printing paper
Clean printing head in sequence.
 
The paper feed is deviated and there is error of the printing curve position. The paper is not placed well
The printing paper of different brands has been used
Adjust the direction and position of printing paper
In the printing control menu, adjust the printing position according to indication