Basic Info
Place of Origin: | China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Wall Mount AC/DC Adapter
Plug-in AC/DC adapter
Light, small, slim, compact design. High power density, high reliability, Green power, full compliant with RoHS, REACH, PAHs, WEEE. Energy efficiency: CEC V, UL, GS, CE, C-TICK, PSE, FCC approved
1) Rated Input: 100-240V AC, 50/60Hz
2) Output voltage: Available from 3VDC to 24VDC
3) Output current: Available from 50mA to 6A
4) Output power: 1-50W
5) RoHS, PAHs, REACH, WEEE compliant
6) 6P, NP available
7) Energy efficiency: V (CEC, EUP, ERP, MEPS)
8) MTBF: 50K hours at 25'C
9) LED indicator: Optional
10) Safety standard: IEC/EN 60950-1, CSA C22.2, UL60950
Plug-in AC/DC adapter
Light, small, slim, compact design. High power density, high reliability, Green power, full compliant with RoHS, REACH, PAHs, WEEE. Energy efficiency: CEC V, UL, GS, CE, C-TICK, PSE, FCC approved
1) Rated Input: 100-240V AC, 50/60Hz
2) Output voltage: Available from 3VDC to 24VDC
3) Output current: Available from 50mA to 6A
4) Output power: 1-50W
5) RoHS, PAHs, REACH, WEEE compliant
6) 6P, NP available
7) Energy efficiency: V (CEC, EUP, ERP, MEPS)
8) MTBF: 50K hours at 25'C
9) LED indicator: Optional
10) Safety standard: IEC/EN 60950-1, CSA C22.2, UL60950
SPECIFICATION | ||
Input | Input voltage | 90-264VAC |
Frequency range | 47-63Hz | |
Inrush current | 50A Max, 120VAC at max load, 80A Max 240VAC at max load | |
Leakage Current | 0.25mA max | |
Energy efficiency | CEC V, EUP 2011, MEPS V | |
Output | Voltage | Available from 3VDC to 24VDC |
Current | Available from 50mA to 6A | |
Power | 1-50W | |
Load regulation | +/-5% | |
Hold-up time | 10ms minimun at 115V AC / full load | |
Connector | DC cable | 2468 2C 6FT or others |
DC plug | Per customer request | |
Protections | Short circuit protection | |
Over voltage protection | ||
Over current protection | ||
Envionmental requirements | Operating Temperature | 0-40° C |
Storage Temperature | -20-80oC | |
Operating Relative humidity | 10-90% RH | |
Others | MTBF | 50K hours at 25' C |
Led indicator | Optional | |
Size | ||
Safety Approvals | UL/cUL/GS/CE/CB/C-TICK/CCC/PSE/EMC/FCC | |
Standards | UL60950-1, IEC/EN60950-1, AS/NZS60950-1, J60950, FCC part 15 class B | |
Compliance | RoHS, PAHS, REACH, WEEE |