Rack Mount Online UPS-High Frequency Online UPS 1KVA-6KVA (UTR)
- Payment Type:
- T/T, Money Gram, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | T/T, Money Gram, Western Union |
Product Description
Product Description
Rack Mount Online UPS-High Frequency Online UPS 1KVA-6KVA
Product Features
IP/OP: 110/115/120VAC 50/60Hz
IP/OP: 220/230/240VAC 50/60Hz
KEY FEATURES
Wide input voltage range
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery
True online double conversion technology with advanced microprocessor control
APPLICATION
Servers, Data-Center, Critical network devices, Sensitive electronic equipment, Telecom, etc
Product performance
TECHNICAL SPECIFICATION
Model UT1KR UT1KRL UT2KR UT2KRL UT3KR UT3KRL UT6KRL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W 6KVA/4200W
Input Voltage (115~300)VAC (176~276)VAC
Frequency 46~54Hz/56~64Hz (Adjustable via LCD panel)
Output Voltage 220/230/240(1± 1%)VAC (Adjustable via LCD panel)
Frequency 50/60Hz (Adjustable via LCD panel)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1± 0.2%)
60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1± 0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥ 5' Depends on the capacity of the external batteries bank ≥ 9' Depends on the capacity of the external batteries bank ≥ 5' Depends on the capacity of the external batteries bank Depends on the capacity of the external batteries bank
Half Load ≥ 14' ≥ 21' ≥ 15'
Battery Nominal Voltage 36VDC 96VDC 240VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms 105%~130% 10min, over 150%1min
Communications RS-232+Intelligent Slot
Operating Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions(W*D*H)mm 482.6*450*88 482.6*600*130
Net Weight(Kg) 16 9 10.5 11.5 11 12.5 19.5
Product Features
IP/OP: 110/115/120VAC 50/60Hz
IP/OP: 220/230/240VAC 50/60Hz
KEY FEATURES
Wide input voltage range
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery
True online double conversion technology with advanced microprocessor control
APPLICATION
Servers, Data-Center, Critical network devices, Sensitive electronic equipment, Telecom, etc
Product performance
TECHNICAL SPECIFICATION
Model UT1KR UT1KRL UT2KR UT2KRL UT3KR UT3KRL UT6KRL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W 6KVA/4200W
Input Voltage (115~300)VAC (176~276)VAC
Frequency 46~54Hz/56~64Hz (Adjustable via LCD panel)
Output Voltage 220/230/240(1± 1%)VAC (Adjustable via LCD panel)
Frequency 50/60Hz (Adjustable via LCD panel)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1± 0.2%)
60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1± 0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥ 5' Depends on the capacity of the external batteries bank ≥ 9' Depends on the capacity of the external batteries bank ≥ 5' Depends on the capacity of the external batteries bank Depends on the capacity of the external batteries bank
Half Load ≥ 14' ≥ 21' ≥ 15'
Battery Nominal Voltage 36VDC 96VDC 240VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms 105%~130% 10min, over 150%1min
Communications RS-232+Intelligent Slot
Operating Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions(W*D*H)mm 482.6*450*88 482.6*600*130
Net Weight(Kg) 16 9 10.5 11.5 11 12.5 19.5